3KV ISOLATED UNREGULATED DUAL OUTPUT DC/DC CONVERTER
FxxxxS-1W SERIES
OUTPUT CHARACTERISTICS
Parameter
Rated Power
2
Voltage Set Point Accuracy
Line regulation
Load Regulation
10% load to rated load, other output types
BW=DC to 20MHz, 5V output types
Ripple and Noise
BW=DC to 20MHz, 9V output types
BW=DC to 20MHz, 12V output types
BW=DC to 20MHz, 15V out put types
85
60
50
40
10
110
75
65
55
mV p-p
TA=-40°C to 85°C
See tolerance envelope
High VIN to low VIN
10% load to rated load, 5V output types
1
1.2
15
%
%/%
Conditions
Min.
Typ.
Max.
1
Units
W
ABSOLUTE MAXIMUM RATINGS
Short-circuit protection
3
Lead temperature 1.5mm from case for 10 seconds
Internal power dissipation
Input voltage VIN, F05 types
Input voltage VIN, F12 types
1 second
300℃
450mW
7V
15V
GENERAL CHARACTERISTICS
Parameter
Switching frequency
Conditions
All input types
Min.
Type
100
Max.
Units
kHz
TEMPERATURE CHARACTERISTICS
Parameter
Specification
Storage
Case Temperature above ambient
Cooling
Conditions
5V & 12V input types
24V & 48V input types
All
5V output types
All other output types
Free air convection
Min.
-40
0
-50
Type
Max.
85
70
150
41
32
°C
Units
ISOLATION CHARACTERISTICS
Parameter
Isolation test voltage
Resistance
1.
2.
3.
Conditions
Flash tested for 1 second
Viso= 500VDC
Min.
3000
10
Type
Max.
Units
VDC
GΩ
Calculated using MIL-HDBK-217F with nominal input voltage at full load.
See derating graph
Supply voltage must be discontinued at the end of the short circuit duration.
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
Copyright Guangzhou Tycem Electronics Limited