3kv ISOLATED UNREGULATED DUAL OUTPUT DC/DC CONVERTER
ExxxxS-1W SERIES
OUTPUT CHARACTERISTICS
Parameter
Rated Power
2
Voltage Set Point Accuracy
Line regulation
TA=-40°C to 85°C
See tolerance envelope
High VIN to low VIN
10% load to rated load, 5V output types
Load Regulation
10% load to rated load, 9V output types
10% load to rated load, 12V output types
10% load to rated load, 15V output types
BW=DC to 20MHz, 5V output types
Ripple and Noise
BW=DC to 20MHz, 9V output types
BW=DC to 20MHz, 12V output types
BW=DC to 20MHz, 15V output types
ABSOLUTE MAXIMUM RATINGS
Short-circuit protection
3
Lead temperature 1.5mm from case for 10 seconds
Internal power dissipation
Input voltage VIN, E05 types
Input voltage VIN, E12 types
1 second
300℃
450mW
7V
15V
1
10
9
6.5
6
40
25
25
20
1.2
12.5
10
7.5
7
75
50
50
50
mV p-p
%
%/%
Conditions
Min.
Typ.
Max.
1
Units
W
GENERAL CHARACTERISTICS
Parameter
Switching frequency
Conditions
All input types
Min.
Type
100
Max.
Units
kHz
TEMPERATURE CHARACTERISTICS
Parameter
Specification
Storage
Case Temperature
above ambient
Cooling
Parameter
Isolation test voltage
Resistance
1.
2.
3.
Conditions
5V & 12V input types
24V & 48V input types
All
5V output types
All other output types
Free air onvection
Min.
-40
0
-50
33
28
Type
Max.
85
70
150
°C
Units
ISOLATION CHARACTERISTICS
Conditions
Flash tested for 1 second
Viso= 500VDC
Min.
3000
10
Type
Max.
Units
VDC
GΩ
Calculated using MIL-HDBK-217F with nominal input voltage at full load.
See derating graph
Supply voltage must be discontinued at the end of the short circuit duration.
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
Copyright Guangzhou Tycem Electronics Limited
Page 2 of 3