欢迎访问ic37.com |
会员登录 免费注册
发布采购

A1205XS-W25 参数 Datasheet PDF下载

A1205XS-W25图片预览
型号: A1205XS-W25
PDF下载: 下载PDF文件 查看货源
内容描述: 0.25W ,定电压输入,隔离非稳压双输出DC- DC转换器 [0.25W, FIXED INPUT, ISOLATED&UNREGULATED DUAL OUTPUT DC-DC CONVERTER]
分类和应用: 转换器输出元件输入元件DC-DC转换器
文件页数/大小: 2 页 / 670 K
品牌: MICRODC [ MICRODC POWER TECHNOLOGY CO., LTD ]
 浏览型号A1205XS-W25的Datasheet PDF文件第1页  
A-XS-W25&B-XLS-W25
Series
ISOLATION SPECIFICATIONS
Item
Isolation voltage
Isolation resistance
Test conditions
Tested for 1 minute and 1 mA max
Test at 500VDC
Min
1000
1000
Typ
Max
Units
VDC
APPLICATION NOTE
Requirement on output load
To ensure this module can operate efficiently and
reliably, During operation, the minimum output load
is not less than 10% of the full load, and that this
product should never be operated under no load! If
the actual output power is very small, please connect
OUTPUT SPECIFICATIONS
Item
Output power
Line regulation
For Vin change
of
±1%
(3.3V input)
(Others input)
(3.3V output)
10% to 100%
Load regulation
load
(12V output)
(15V output)
Output voltage
accuracy
a resistor with proper resistance at the output end in
Min
Typ
Max
0.25
±1.5
±1.2
12
10.5
8.3
6.8
6.3
20
15
15
15
15
Recommended circuit
If you want to further decrease the input/output
ripple, an "LC" filtering network may be connected to
the input and output ends of the DC/DC converter,
%/℃
mVp-p
KHz
see (Figure 1).
%
Units
W
parallel to increase the load.
Overload Protection
Under normal operating conditions, the output
circuit of these products has no protection against
overload. The simplest method is to connect a
self-recovery fuse in series at the input end or add a
circuit breaker to the circuit.
(5V output)
(9V output)
Test conditions
See tolerance envelope graph
100% full load
20MHz Bandwidth
Full load, nominal input
50
100
0.03
75
Temperature drift
Ripple & Noise*
Switching frequency
*Test ripple and noise by "parallel cable" method. See detailed operation instructions at Testing .
Note:
1. All specifications measured at T A =25℃, humidity<75%, nominal input voltage and rated output load unless otherwise
specified.
2. See below recommended circuits for more details.
3. Dual output models unbalanced load:
±5%.
TYPICAL CHARACTERISTICS
it should also be noted that the inductance and the
frequency of the "LC" filtering network should be
staggered with the DC/DC frequency to avoid mutual
interference. However, the capacitance of the output
filter capacitor must be proper. If the capacitance is
too big, a startup problem might arise. It's not
recommended to connect any external capacitor in
the application field.
Output Voltage Regulation and
Protection Circuit
Over-voltage
OUTLINE DIMENSIONS & PIN CONNECTIONS
The simplest device for output voltage regulation,
over-voltage and over-current protection is a linear
voltage regulator with overheat protection that is
connected to the input or output end in series (Figure
2).
No parallel connection or plug and play.
Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646
Page 2 of 2