 浏览型号PIC18F4580-I/PT的Datasheet PDF文件第182页浏览型号PIC18F4580-I/PT的Datasheet PDF文件第183页浏览型号PIC18F4580-I/PT的Datasheet PDF文件第184页浏览型号PIC18F4580-I/PT的Datasheet PDF文件第185页浏览型号PIC18F4580-I/PT的Datasheet PDF文件第187页浏览型号PIC18F4580-I/PT的Datasheet PDF文件第188页浏览型号PIC18F4580-I/PT的Datasheet PDF文件第189页浏览型号PIC18F4580-I/PT的Datasheet PDF文件第190页  
PIC18F2480/2580/4480/4580  
When  
a shutdown occurs, the output pins are  
17.4.6  
PROGRAMMABLE DEAD-BAND  
DELAY  
asynchronously placed in their shutdown states,  
specified by the PSSAC<1:0> and PSS1BD<1:0> bits  
(ECCPAS<3:0>). Each pin pair (P1A/P1C and P1B/P1D)  
may be set to drive high, drive low or be tri-stated (not  
driving). The ECCPASE bit (ECCP1AS<7>) is also set to  
hold the Enhanced PWM outputs in their shutdown  
states.  
Note:  
Programmable dead-band delay is not  
implemented in PIC18F2X80 devices with  
standard CCP modules.  
In half-bridge applications where all power switches are  
modulated at the PWM frequency at all times, the power  
switches normally require more time to turn off than to  
turn on. If both the upper and lower power switches are  
switched at the same time (one turned on and the other  
turned off), both switches may be on for a short period of  
time until one switch completely turns off. During this  
brief interval, a very high current (shoot-through current)  
may flow through both power switches, shorting the  
bridge supply. To avoid this potentially destructive  
shoot-through current from flowing during switching,  
turning on either of the power switches is normally  
delayed to allow the other switch to completely turn off.  
The ECCPASE bit is set by hardware when a shutdown  
event occurs. If automatic restarts are not enabled, the  
ECCPASE bit is cleared by firmware when the cause of  
the shutdown clears. If automatic restarts are enabled,  
the ECCPASE bit is automatically cleared when the  
cause of the auto-shutdown has cleared.  
If the ECCPASE bit is set when a PWM period begins,  
the PWM outputs remain in their shutdown state for that  
entire PWM period. When the ECCPASE bit is cleared,  
the PWM outputs will return to normal operation at the  
beginning of the next PWM period.  
In the Half-Bridge Output mode, a digitally program-  
mable, dead-band delay is available to avoid  
shoot-through current from destroying the bridge  
power switches. The delay occurs at the signal transi-  
tion from the non-active state to the active state (see  
Figure 17-4 for illustration). Bits, PDC<6:0< of the  
ECCP1DEL register (Register 17-2), set the delay  
period in terms of microcontroller instruction cycles  
(TCY or 4 TOSC). These bits are not available on  
PIC18F2X80 devices, as the standard CCP module  
does not support half-bridge operation.  
Note:  
Writing to the ECCPASE bit is disabled  
while a shutdown condition is active.  
Note:  
If the dead-band delay value is increased  
after the dead-band time has elapsed, that  
new value takes effect immediately. This  
happens even if the PWM pulse is high  
and can appear to be a glitch. Dead-band  
values must be changed during the  
dead-band time or before ECCP is active  
17.4.7  
ENHANCED PWM AUTO-SHUTDOWN  
When the CCP1 is programmed for any of the Enhanced  
PWM modes, the active output pins may be configured  
for auto-shutdown. Auto-shutdown immediately places  
the Enhanced PWM output pins into a defined shutdown  
state when a shutdown event occurs.  
A shutdown event can be caused by either of the  
comparator modules,  
a
low level on the  
RB0/INT0/FLT0/AN10 pin, or any combination of these  
three sources. The comparators may be used to monitor  
a voltage input proportional to a current being monitored  
in the bridge circuit. If the voltage exceeds a threshold,  
the comparator switches state and triggers a shutdown.  
Alternatively, a digital signal on the INT0 pin can also  
trigger a shutdown. The auto-shutdown feature can be  
disabled by not selecting any auto-shutdown sources.  
The auto-shutdown sources to be used are selected  
using the ECCPAS<2:0> bits (ECCP1AS<6:4>).  
DS39637D-page 186  
© 2009 Microchip Technology Inc.  