 浏览型号PIC18F4520-I/P的Datasheet PDF文件第128页浏览型号PIC18F4520-I/P的Datasheet PDF文件第129页浏览型号PIC18F4520-I/P的Datasheet PDF文件第130页浏览型号PIC18F4520-I/P的Datasheet PDF文件第131页浏览型号PIC18F4520-I/P的Datasheet PDF文件第133页浏览型号PIC18F4520-I/P的Datasheet PDF文件第134页浏览型号PIC18F4520-I/P的Datasheet PDF文件第135页浏览型号PIC18F4520-I/P的Datasheet PDF文件第136页  
PIC18F2420/2520/4420/4520  
12.3.3  
TIMER1 OSCILLATOR LAYOUT  
CONSIDERATIONS  
12.5 Resetting Timer1 Using the CCP  
Special Event Trigger  
The Timer1 oscillator circuit draws very little power  
during operation. Due to the low-power nature of the  
oscillator, it may also be sensitive to rapidly changing  
signals in close proximity.  
If either of the CCP modules is configured to use  
Timer1 and generate a Special Event Trigger in Com-  
pare mode (CCP1M<3:0> or CCP2M<3:0> = 1011),  
this signal will reset Timer1. The trigger from CCP2 will  
also start an A/D conversion if the A/D module is  
enabled (see Section 15.3.4 “Special Event Trigger”  
for more information).  
The oscillator circuit, shown in Figure 12-3, should be  
located as close as possible to the microcontroller.  
There should be no circuits passing within the oscillator  
circuit boundaries other than VSS or VDD.  
The module must be configured as either a timer or a  
synchronous counter to take advantage of this feature.  
When used this way, the CCPRxH:CCPRxL register  
pair effectively becomes a Period register for Timer1.  
If a high-speed circuit must be located near the oscilla-  
tor (such as the CCP1 pin in Output Compare or PWM  
mode, or the primary oscillator using the OSC2 pin), a  
grounded guard ring around the oscillator circuit, as  
shown in Figure 12-4, may be helpful when used on a  
single-sided PCB or in addition to a ground plane.  
If Timer1 is running in Asynchronous Counter mode,  
this Reset operation may not work.  
In the event that a write to Timer1 coincides with a  
Special Event Trigger, the write operation will take  
precedence.  
FIGURE 12-4:  
OSCILLATOR CIRCUIT  
WITH GROUNDED  
GUARD RING  
Note:  
The Special Event Triggers from the CCP2  
module will not set the TMR1IF interrupt  
flag bit (PIR1<0>).  
VDD  
VSS  
12.6 Using Timer1 as a Real-Time Clock  
OSC1  
OSC2  
Adding an external LP oscillator to Timer1 (such as the  
one described in Section 12.3 “Timer1 Oscillator”)  
gives users the option to include RTC functionality to  
their applications. This is accomplished with an  
inexpensive watch crystal to provide an accurate time  
base and several lines of application code to calculate  
the time. When operating in Sleep mode and using a  
battery or supercapacitor as a power source, it can  
completely eliminate the need for a separate RTC  
device and battery backup.  
RC0  
RC1  
RC2  
The application code routine, RTCisr, shown in  
Example 12-1, demonstrates a simple method to  
increment a counter at one-second intervals using an  
Interrupt Service Routine. Incrementing the TMR1  
register pair to overflow triggers the interrupt and calls  
the routine, which increments the seconds counter by  
one; additional counters for minutes and hours are  
incremented as the previous counter overflow.  
Note: Not drawn to scale.  
12.4 Timer1 Interrupt  
The TMR1 register pair (TMR1H:TMR1L) increments  
from 0000h to FFFFh and rolls over to 0000h. The  
Timer1 interrupt, if enabled, is generated on overflow,  
which is latched in interrupt flag bit, TMR1IF  
(PIR1<0>). This interrupt can be enabled or disabled  
by setting or clearing the Timer1 Interrupt Enable bit,  
TMR1IE (PIE1<0>).  
Since the register pair is 16 bits wide, counting up to  
overflow the register directly from a 32.768 kHz clock  
would take 2 seconds. To force the overflow at the  
required one-second intervals, it is necessary to pre-  
load it. The simplest method is to set the MSb of  
TMR1H with a BSF instruction. Note that the TMR1L  
register is never preloaded or altered; doing so may  
introduce cumulative error over many cycles.  
For this method to be accurate, Timer1 must operate in  
Asynchronous mode and the Timer1 overflow interrupt  
must be enabled (PIE1<0> = 1), as shown in the  
routine, RTCinit. The Timer1 oscillator must also be  
enabled and running at all times.  
DS39631E-page 130  