 浏览型号PIC18F8620-I/PT的Datasheet PDF文件第218页浏览型号PIC18F8620-I/PT的Datasheet PDF文件第219页浏览型号PIC18F8620-I/PT的Datasheet PDF文件第220页浏览型号PIC18F8620-I/PT的Datasheet PDF文件第221页浏览型号PIC18F8620-I/PT的Datasheet PDF文件第223页浏览型号PIC18F8620-I/PT的Datasheet PDF文件第224页浏览型号PIC18F8620-I/PT的Datasheet PDF文件第225页浏览型号PIC18F8620-I/PT的Datasheet PDF文件第226页  
PIC18FXX20  
19.4 A/D Conversions  
19.5 Use of the CCP2 Trigger  
Figure 19-3 shows the operation of the A/D converter  
after the GO bit has been set. Clearing the GO/DONE  
bit during a conversion will abort the current conver-  
sion. The A/D result register pair will NOT be updated  
with the partially completed A/D conversion sample.  
That is, the ADRESH:ADRESL registers will continue  
to contain the value of the last completed conversion  
(or the last value written to the ADRESH:ADRESL reg-  
isters). After the A/D conversion is aborted, a 2 TAD wait  
is required before the next acquisition is started. After  
this 2 TAD wait, acquisition on the selected channel is  
automatically started.  
An A/D conversion can be started by the “special event  
trigger” of the CCP2 module. This requires that the  
CCP2M3:CCP2M0 bits (CCP2CON<3:0>) be pro-  
grammed as 1011and that the A/D module is enabled  
(ADON bit is set). When the trigger occurs, the  
GO/DONE bit will be set, starting the A/D conversion,  
and the Timer1 (or Timer3) counter will be reset to zero.  
Timer1 (or Timer3) is reset to automatically repeat the  
A/D acquisition period with minimal software overhead  
(moving ADRESH/ADRESL to the desired location).  
The appropriate analog input channel must be selected  
and the minimum acquisition done before the “special  
event trigger” sets the GO/DONE bit (starts a  
conversion).  
Note: The GO/DONE bit should NOT be set in  
the same instruction that turns on the A/D.  
If the A/D module is not enabled (ADON is cleared), the  
“special event trigger” will be ignored by the A/D module,  
but will still reset the Timer1 (or Timer3) counter.  
FIGURE 19-3:  
A/D CONVERSION TAD CYCLES  
TCY - TAD  
TAD7 TAD8 TAD9 TAD10 TAD11  
TAD1 TAD2 TAD3 TAD4 TAD5 TAD6  
b0  
b5  
b4  
b3  
b2  
b1  
b0  
b7  
b6  
b8  
b9  
Conversion Starts  
Holding capacitor is disconnected from analog input (typically 100 ns)  
Set GO bit  
Next Q4: ADRESH/ADRESL is loaded, GO bit is cleared,  
ADIF bit is set, holding capacitor is connected to analog input.  
DS39609A-page 220  
Advance Information  
2003 Microchip Technology Inc.  