 浏览型号PIC18F8620-I/PT的Datasheet PDF文件第149页浏览型号PIC18F8620-I/PT的Datasheet PDF文件第150页浏览型号PIC18F8620-I/PT的Datasheet PDF文件第151页浏览型号PIC18F8620-I/PT的Datasheet PDF文件第152页浏览型号PIC18F8620-I/PT的Datasheet PDF文件第154页浏览型号PIC18F8620-I/PT的Datasheet PDF文件第155页浏览型号PIC18F8620-I/PT的Datasheet PDF文件第156页浏览型号PIC18F8620-I/PT的Datasheet PDF文件第157页  
PIC18FXX20  
16.2.3  
SOFTWARE INTERRUPT  
16.2 Capture Mode  
When the Capture mode is changed, a false capture  
interrupt may be generated. The user should keep bit  
CCP1IE (PIE1<2>) clear to avoid false interrupts and  
should clear the flag bit, CCP1IF, following any such  
change in Operating mode.  
In Capture mode, CCPR1H:CCPR1L captures the  
16-bit value of the TMR1 or TMR3 registers when an  
event occurs on pin RC2/CCP1. An event is defined as  
one of the following:  
• every falling edge  
• every rising edge  
16.2.4  
CCP PRESCALER  
• every 4th rising edge  
• every 16th rising edge  
There are four prescaler settings, specified by bits  
CCP1M3:CCP1M0. Whenever the CCP module is  
turned off or the CCP module is not in Capture mode,  
the prescaler counter is cleared. This means that any  
RESET will clear the prescaler counter.  
Switching from one capture prescaler to another may  
generate an interrupt. Also, the prescaler counter will  
not be cleared, therefore, the first capture may be from  
a non-zero prescaler. Example 16-1 shows the recom-  
mended method for switching between capture pres-  
calers. This example also clears the prescaler counter  
and will not generate the “false” interrupt.  
The event is selected by control bits, CCP1M3:CCP1M0  
(CCP1CON<3:0>). When a capture is made, the inter-  
rupt request flag bit, CCP1IF (PIR1<2>), is set; it must  
be cleared in software. If another capture occurs before  
the value in register CCPR1 is read, the old captured  
value is overwritten by the new captured value.  
16.2.1  
CCP PIN CONFIGURATION  
In Capture mode, the RC2/CCP1 pin should be  
configured as an input by setting the TRISC<2> bit.  
Note: If the RC2/CCP1 is configured as an out-  
put, a write to the port can cause a capture  
condition.  
EXAMPLE 16-1:  
CHANGING BETWEEN  
CAPTURE PRESCALERS  
CLRF  
CCP1CON, F ; Turn CCP module off  
NEW_CAPT_PS; Load WREG with the  
; new prescaler mode  
MOVLW  
16.2.2  
TIMER1/TIMER3 MODE SELECTION  
The timers that are to be used with the capture feature  
(Timer1 and/or Timer3) must be running in Timer mode,  
or Synchronized Counter mode. In Asynchronous  
Counter mode, the capture operation may not work.  
The timer to be used with each CCP module is selected  
in the T3CON register (see Section 16.1.1).  
; value and CCP ON  
; Load CCP1CON with  
; this value  
MOVWF CCP1CON  
FIGURE 16-2:  
CAPTURE MODE OPERATION BLOCK DIAGRAM  
TMR3H  
TMR3L  
CCPR1L  
TMR1L  
Set Flag bit CCP1IF  
T3CCP2  
TMR3  
Enable  
Prescaler  
÷ 1, 4, 16  
CCP1 pin  
CCPR1H  
TMR1  
and  
Edge Detect  
Enable  
T3CCP2  
TMR1H  
CCP1CON<3:0>  