 浏览型号PIC18LF4320-I/ML的Datasheet PDF文件第253页浏览型号PIC18LF4320-I/ML的Datasheet PDF文件第254页浏览型号PIC18LF4320-I/ML的Datasheet PDF文件第255页浏览型号PIC18LF4320-I/ML的Datasheet PDF文件第256页浏览型号PIC18LF4320-I/ML的Datasheet PDF文件第258页浏览型号PIC18LF4320-I/ML的Datasheet PDF文件第259页浏览型号PIC18LF4320-I/ML的Datasheet PDF文件第260页浏览型号PIC18LF4320-I/ML的Datasheet PDF文件第261页  
PIC18F2220/2320/4220/4320  
The control instructions may use some of the following  
operands:  
24.0 INSTRUCTION SET SUMMARY  
The PIC18 instruction set adds many enhancements to  
the previous PICmicro instruction sets, while maintain-  
ing an easy migration from these PICmicro instruction  
sets.  
• A program memory address (specified by ‘n’)  
• The mode of the CALLor RETURNinstructions  
(specified by ‘s’)  
• The mode of the table read and table write  
instructions (specified by ‘m’)  
Most instructions are a single program memory word  
(16 bits) but there are three instructions that require two  
program memory locations.  
• No operand required  
(specified by ‘—’)  
Each single-word instruction is a 16-bit word divided  
into an opcode, which specifies the instruction type and  
one or more operands, which further specify the oper-  
ation of the instruction.  
All instructions are a single word except for three dou-  
ble word instructions. These three instructions were  
made double word instructions so that all the required  
information is available in these 32 bits. In the second  
word, the 4 MSbs are ‘1’s. If this second word is  
executed as an instruction (by itself), it will execute as  
a NOP.  
The instruction set is highly orthogonal and is grouped  
into four basic categories:  
Byte-oriented operations  
Bit-oriented operations  
Literal operations  
All single-word instructions are executed in a single  
instruction cycle, unless a conditional test is true or the  
program counter is changed as a result of the instruc-  
tion. In these cases, the execution takes two instruction  
cycles with the additional instruction cycle(s) executed  
as a NOP.  
Control operations  
The PIC18 instruction set summary in Table 24-2 lists  
byte-oriented, bit-oriented, literal and control opera-  
tions. Table 24-1 shows the opcode field descriptions.  
The double word instructions execute in two instruction  
cycles.  
Most byte-oriented instructions have three operands:  
1. The file register (specified by ‘f’)  
One instruction cycle consists of four oscillator periods.  
Thus, for an oscillator frequency of 4 MHz, the normal  
instruction execution time is 1 µs. If a conditional test is  
true, or the program counter is changed as a result of  
an instruction, the instruction execution time is 2 µs.  
Two-word branch instructions (if true) would take 3 µs.  
2. The destination of the result  
(specified by ‘d’)  
3. The accessed memory  
(specified by ‘a’)  
The file register designator ‘f’ specifies which file  
register is to be used by the instruction.  
Figure 24-1 shows the general formats that the  
instructions can have.  
The destination designator ‘d’ specifies where the  
result of the operation is to be placed. If ‘d’ is zero, the  
result is placed in the WREG register. If ‘d’ is one, the  
result is placed in the file register specified in the  
instruction.  
All examples use the format ‘nnh’ to represent a hexa-  
decimal number, where ‘h’ signifies a hexadecimal  
digit.  
The Instruction Set Summary, shown in Table 24-2,  
lists the instructions recognized by the Microchip  
Assembler (MPASMTM). Section 24.2 “Instruction  
Set” provides a description of each instruction.  
All bit-oriented instructions have three operands:  
1. The file register (specified by ‘f’)  
2. The bit in the file register  
(specified by ‘b’)  
24.1 READ-MODIFY-WRITE OPERATIONS  
3. The accessed memory  
(specified by ‘a’)  
Any instruction that specifies a file register as part of  
the instruction performs a Read-Modify-Write (R-M-W)  
operation. The register is read, the data is modified and  
the result is stored according to either the instruction or  
the destination designator ‘d’. A read operation is per-  
formed on a register even if the instruction writes to that  
register.  
The bit field designator ‘b’ selects the number of the bit  
affected by the operation, while the file register desig-  
nator ‘f’ represents the number of the file in which the  
bit is located.  
The literal instructions may use some of the following  
operands:  
For example, a “BCF PORTB,1” instruction will read  
PORTB, clear bit 1 of the data, then write the result  
back to PORTB. The read operation would have the  
unintended result that any condition that sets the RBIF  
flag would be cleared. The R-M-W operation may also  
copy the level of an input pin to its corresponding output  
latch.  
• A literal value to be loaded into a file register  
(specified by ‘k’)  
• The desired FSR register to load the literal value  
into (specified by ‘f’)  
• No operand required  
(specified by ‘—’)  