 浏览型号PIC16F630-I/ST的Datasheet PDF文件第57页浏览型号PIC16F630-I/ST的Datasheet PDF文件第58页浏览型号PIC16F630-I/ST的Datasheet PDF文件第59页浏览型号PIC16F630-I/ST的Datasheet PDF文件第60页浏览型号PIC16F630-I/ST的Datasheet PDF文件第62页浏览型号PIC16F630-I/ST的Datasheet PDF文件第63页浏览型号PIC16F630-I/ST的Datasheet PDF文件第64页浏览型号PIC16F630-I/ST的Datasheet PDF文件第65页  
PIC16F630/676  
On any RESET (Power-on, Brown-out Detect,  
Watchdog, etc.), the chip will remain in RESET until  
VDD rises above BVDD (see Figure 9-6). The Power-up  
Timer will now be invoked, if enabled, and will keep the  
chip in RESET an additional 72 ms.  
9.3.5  
BROWN-OUT DETECT (BOD)  
The PIC16F630/676 members have on-chip Brown-out  
Detect circuitry. A configuration bit, BODEN, can  
disable (if clear/programmed) or enable (if set) the  
Brown-out Detect circuitry. If VDD falls below VBOD for  
greater than parameter (TBOD) in Table 12-4 (see  
Section 12.0), the Brown-out situation will reset the  
device. This will occur regardless of VDD slew-rate. A  
RESET is not guaranteed to occur if VDD falls below  
VBOD for less than parameter (TBOD).  
Note: A Brown-out Detect does not enable the  
Power-up Timer if the PWRTE bit in the  
configuration word is set.  
If VDD drops below BVDD while the Power-up Timer is  
running, the chip will go back into a Brown-out Detect  
and the Power-up Timer will be re-initialized. Once VDD  
rises above BVDD, the Power-up Timer will execute a  
72 ms RESET.  
FIGURE 9-6:  
BROWN-OUT SITUATIONS  
VDD  
VBOD  
Internal  
RESET  
72 ms(1)  
VDD  
VBOD  
Internal  
RESET  
<72 ms  
72 ms(1)  
VDD  
VBOD  
Internal  
RESET  
72 ms(1)  
Note 1: 72 ms delay only if PWRTE bit is programmed to ‘0’.  
9.3.6  
TIME-OUT SEQUENCE  
9.3.7  
POWER CONTROL (PCON) STATUS  
REGISTER  
On power-up, the time-out sequence is as follows: first,  
PWRT time-out is invoked after POR has expired.  
Then, OST is activated. The total time-out will vary  
based on oscillator configuration and PWRTE bit  
status. For example, in EC mode with PWRTE bit  
erased (PWRT disabled), there will be no time-out at  
all. Figure 9-7, Figure 9-8 and Figure 9-9 depict time-  
out sequences.  
The power CONTROL/STATUS register, PCON  
(address 8Eh) has two bits.  
Bit0 is BOD (Brown-out). BOD is unknown on Power-  
on Reset. It must then be set by the user and checked  
on subsequent RESETS to see if BOD = 0, indicating  
that a brown-out has occurred. The BOD STATUS bit is  
a don’t care and is not necessarily predictable if the  
brown-out circuit is disabled (by setting BODEN bit = 0  
in the Configuration word).  
Since the time-outs occur from the POR pulse, if MCLR  
is kept low long enough, the time-outs will expire. Then  
bringing MCLR high will begin execution immediately  
(see Figure 9-8). This is useful for testing purposes or  
to synchronize more than one PIC16F630/676 device  
operating in parallel.  
Bit1 is POR (Power-on Reset). It is a ‘0’ on Power-on  
Reset and unaffected otherwise. The user must write a  
‘1’ to this bit following a Power-on Reset. On a  
subsequent RESET, if POR is ‘0’, it will indicate that a  
Power-on Reset must have occurred (i.e., VDD may  
have gone too low).  
Table 9-6 shows the RESET conditions for some  
special registers, while Table 9-7 shows the RESET  
conditions for all the registers.  