PIC16C62B/72A
2.2.2.6
PCON REGISTER
Note: On Power-on Reset, the state of the BOR
bit is unknown and is not predictable.
If the BODEN bit in the configuration word
is set, the user must first set the BOR bit on
a POR, and check it on subsequent resets.
If BOR is cleared while POR remains set,
a Brown-out reset has occurred.
The Power Control register (PCON) contains flag bits to
allow differentiation between a Power-on Reset (POR),
Brown-Out Reset (BOR) and resets from other
sources. .
If the BODEN bit is clear, the BOR bit may
be ignored.
REGISTER 2-6: PCON REGISTER (ADDRESS 8Eh)
U-0
U-0
U-0
U-0
U-0
U-0
R/W-0
R/W-q
—
—
—
—
—
—
POR
BOR
R
= Readable bit
W = Writable bit
bit7
bit0
U
= Unimplemented bit,
read as ‘0’
- n = Value at POR reset
bit 7-2: Unimplemented: Read as ’0’
bit 1:
POR: Power-on Reset Status bit
1= No Power-on Reset occurred
0= A Power-on Reset occurred (must be set in software after a Power-on Reset occurs)
bit 0:
BOR: Brown-out Reset Status bit
1= No Brown-out Reset occurred
0= A Brown-out Reset occurred (must be set in software after a Brown-out Reset occurs)
DS35008B-page 16
Preliminary