MCP9808  
5.2  
SENSOR FEATURE DESCRIPTION  
VDD  
5.2.1  
SHUTDOWN MODE  
MCP9808  
Shutdown mode disables all power consuming  
activities (including temperature sampling operations)  
while leaving the serial interface active. This mode is  
selected by setting bit 8 of CONFIG to ‘1’. In this mode,  
the device consumes ISHDN. It remains in this mode  
until bit 8 is cleared to ‘0’ to enable Continuous  
Conversion mode or until power is recycled.  
RPU  
Alert Output  
The Shutdown bit (bit 8) cannot be set to ‘1’ while the  
CONFIG<7:6> bits (Lock bits) are set to ‘1’. However, it  
can be cleared to ‘0’ or returned to Continuous  
Conversion mode while locked.  
FIGURE 5-9:  
Configuration.  
Active-Low Alert Output  
The status of the Alert output can be read using  
CONFIG<4> (Alert Output Status bit). This bit can not  
be set to ‘1’ in Shutdown mode.  
In Shutdown mode, all registers can be read or written.  
However, the serial bus activity increases the shutdown  
current. In addition, if the device is in shutdown while  
the Alert pin is asserted, the device will retain the active  
state during shutdown. This increases the shutdown  
current due to the additional Alert output current.  
Bits 7 and 6 of the CONFIG register can be used to lock  
the TUPPER, TLOWER and TCRIT registers. These bits  
prevent false triggers at the Alert output due to an  
accidental rewrite to these registers.  
The Alert output can also be used as a critical temper-  
ature output using bit 2 of CONFIG (Alert Output Select  
bit). When this feature is selected, the Alert output  
becomes a comparator output. In this mode, the  
interrupt output configuration (Alert Output Mode bit,  
CONFIG<0>) is ignored.  
5.2.2  
TEMPERATURE HYSTERESIS  
(THYST  
)
A hysteresis of 0°C, +1.5°C, +3°C or +6°C can be  
selected for the TUPPER, TLOWER and TCRIT temperate  
boundaries, using bits 10 and 9 of CONFIG. The  
hysteresis applies for decreasing temperature only (hot  
to cold) or as temperature drifts below the specified  
limit.  
5.2.3.1  
Comparator Mode  
Comparator mode is selected using bit 0 of CONFIG. In  
this mode, the Alert output is asserted as active-high or  
active-low, using bit 1 of CONFIG. Figure 5-10 shows  
the conditions that toggle the Alert output.  
The Hysteresis bits can not be changed if either of the  
Lock bits (CONFIG<7:6) are set to ‘1’.  
The TUPPER, TLOWER and TCRIT boundary conditions  
are described graphically in Figure 5-10.  
If the device enters Shutdown mode with asserted Alert  
output, the output remains asserted during Shutdown  
mode. The device must be operating in Continuous  
5.2.3  
ALERT OUTPUT CONFIGURATION  
Conversion mode for tCONV. The TA vs. TUPPER  
,
The Alert output can be enabled by using bit 3 of the  
CONFIG register (Alert Output Control bit) and can be  
configured as either a comparator output or as an  
Interrupt Output mode using bit 0 of CONFIG (Alert  
Output Mode bit). The polarity can also be specified as  
active-high or active-low using bit 1 of CONFIG (Alert  
Polarity bit). This is an open-drain output and requires  
a pull-up resistor.  
TLOWER and TCRIT boundary conditions need to be  
satisfied in order for the Alert output to deassert.  
Comparator mode is useful for thermostat type  
applications, such as turning on a cooling fan or  
triggering a system shutdown when the temperature  
exceeds a safe operating range.  
When the ambient temperature increases above the  
critical temperature limit, the Alert output is forced to a  
comparator output (regardless of CONFIG<0>). When  
the temperature drifts below the critical temperature  
limit minus hysteresis, the Alert output automatically  
returns to the state specified by CONFIG<0> bit.  