欢迎访问ic37.com |
会员登录 免费注册
发布采购

MCP4232T-503E/MF 参数 Datasheet PDF下载

MCP4232T-503E/MF图片预览
型号: MCP4232T-503E/MF
PDF下载: 下载PDF文件 查看货源
内容描述: 7/8位单/双SPI数字电位器具有易失性存储器 [7/8-Bit Single/Dual SPI Digital POT with Volatile Memory]
分类和应用: 转换器电位器数字电位计存储电阻器光电二极管
文件页数/大小: 88 页 / 2525 K
品牌: MICROCHIP [ MICROCHIP ]
 浏览型号MCP4232T-503E/MF的Datasheet PDF文件第34页浏览型号MCP4232T-503E/MF的Datasheet PDF文件第35页浏览型号MCP4232T-503E/MF的Datasheet PDF文件第36页浏览型号MCP4232T-503E/MF的Datasheet PDF文件第37页浏览型号MCP4232T-503E/MF的Datasheet PDF文件第39页浏览型号MCP4232T-503E/MF的Datasheet PDF文件第40页浏览型号MCP4232T-503E/MF的Datasheet PDF文件第41页浏览型号MCP4232T-503E/MF的Datasheet PDF文件第42页  
MCP413X/415X/423X/425X  
A POR/BOR event will load the Volatile Wiper register  
value with the default value. Table 5-2 shows the  
default values offered. Custom POR/BOR options are  
available. Contact the local Microchip Sales Office.  
5.2  
Wiper  
Each tap point (between the RS resistors) is a  
connection point for an analog switch. The opposite  
side of the analog switch is connected to a common  
signal which is connected to the Terminal W (Wiper)  
pin.  
TABLE 5-2:  
DEFAULT FACTORY  
SETTINGS SELECTION  
A value in the volatile wiper register selects which  
analog switch to close, connecting the W terminal to  
the selected node of the resistor ladder.  
Wiper Code  
The wiper can connect directly to Terminal B or to  
Terminal A. A zero-scale connections, connects the  
Terminal W (wiper) to Terminal B (wiper setting of  
000h). A full-scale connections, connects the Terminal  
W (wiper) to Terminal A (wiper setting of 100h or 80h).  
In these configurations the only resistance between the  
Terminal W and the other Terminal (A or B) is that of the  
analog switches.  
8-bit  
7-bit  
-502  
-103  
-503  
-104  
5.0 kΩ  
Mid-scale  
Mid-scale  
Mid-scale  
Mid-scale  
80h  
80h  
80h  
80h  
40h  
40h  
40h  
40h  
10.0 kΩ  
50.0 kΩ  
100.0 kΩ  
A wiper setting value greater than full-scale (wiper  
setting of 100h for 8-bit device or 80h for 7-bit devices)  
will also be a Full-Scale setting (Terminal W (wiper)  
connected to Terminal A). Table 5-1 illustrates the full  
wiper setting map.  
Equation 5-2 illustrates the calculation used to deter-  
mine the resistance between the wiper and terminal B.  
EQUATION 5-2:  
R
CALCULATION  
WB  
RAB  
N
RWB = ------------- + RW  
8-bit Device  
(256)  
N = 0 to 256 (decimal)  
RAB  
N
7-bit Device  
RWB = ------------- + RW  
(128)  
N = 0 to 128 (decimal)  
TABLE 5-1:  
VOLATILE WIPER VALUE VS.  
WIPER POSITION MAP  
Wiper Setting  
7-bit Pot 8-bit Pot  
Properties  
3FFh  
081h  
3FFh  
101h  
Reserved (Full-Scale (W = A)),  
Increment and Decrement  
commands ignored  
080h  
100h  
Full-Scale (W = A),  
Increment commands ignored  
07Fh  
041h  
0FFh  
081  
W = N  
040h  
080h  
W = N (Mid-Scale)  
W = N  
03Fh  
001h  
07Fh  
001  
000h  
000h  
Zero Scale (W = B)  
Decrement command ignored  
DS22060B-page 38  