MCP2210
3.1.4
SET USB MANUFACTURER NAME
TABLE 3-11: COMMAND STRUCTURE
Byte
Index
Meaning
0
1
2
3
4
0x60 – Set Chip NVRAM Parameters – command code
0x50 – Set USB Manufacturer Name – sub-command code
0x00 – Reserved
0x00 – Reserved
Total USB String Descriptor Length (this is the length of the Manufacturer string, multiplied by 2 + 2)
Example: “Microchip Technology Inc.” has 25 Unicode characters.
- The value to be filled in is: (25 x 2) + 2 = 52 (decimal) = 0x34
5
6
USB String Descriptor ID – always fill with 0x03
Unicode Character Low Byte
Example: For the “Microchip Technology Inc.” Unicode string, place here the low byte of the Unicode
for character “M”.
- Fill this index with 0x4D
7
Unicode Character High Byte
Example: For the “Microchip Technology Inc.” Unicode string, place here the high byte of the Unicode
for character “M”.
- Fill this index with 0x00
8-63
Fill in the remaining Unicode characters in the string
3.1.4.1
Responses
TABLE 3-12: RESPONSE 1 STRUCTURE
Byte
Index
Meaning
0
1
0x60 – Set Chip NVRAM Parameters – echos back the given command code
0xFB – Blocked Access – The provided password is not matching the one stored in the chip or the
settings are permanently locked.
2-63
Don’t Care
TABLE 3-13: RESPONSE 2 STRUCTURE
Byte
Index
Meaning
0
1
0x60 – Set Chip NVRAM Parameters – echos back the given command code
0x00 – Command Completed Successfully – settings written
0x50 – Sub-command Echoed Back for Set USB Manufacturer Name code
Don’t Care
2
3-63
DS22288A-page 20
2011 Microchip Technology Inc.