Micrel, Inc.
KSZ8041NL
Timing Diagrams
MII SQE Timing (10Base-T)
Figure 7. MII SQE Timing (10Base-T)
Timing Parameter
Description
Min
Typ
400
200
200
2.5
Max
Unit
ns
tP
TXC period
tWL
TXC pulse width low
ns
tWH
tSQE
tSQEP
TXC pulse width high
ns
COL (SQE) delay after TXEN de-asserted
COL (SQE) pulse duration
us
1.0
us
Table 6. MII SQE Timing (10Base-T) Parameters