27.2.1 Using the Power Reduction Register
The tables and formulas below can be used to calculate the additional current consumption for the different I/O modules in
Idle mode. The enabling or disabling of the I/O modules are controlled by the power reduction register. See Section 6.6
“Power Reduction Register” on page 36 for details.
Table 27-1. Additional Current Consumption (Percentage) in Active and Idle Mode
Typical ICC (µA)
Percent of Added Consumption
VCC = 5.0V, 16Mhz
VCC = 3.0V, 8Mhz
PRCAN
PRPSC
PRTIM1
PRTIM0
PRSPI
13
8
12
7.5
2
2
1
1
2
2
PRLIN
5.5
5
5
PRADC
4.5
27.3 Power-down Supply Current
Figure 27-9. Power-down Supply Current versus VCC (Watchdog Timer Disabled)
Figure 27-10. Power-down Supply Current versus VCC (Watchdog Timer Enabled)
ATmega16/32/64/M1/C1 [DATASHEET]
287
7647O–AVR–01/15