PIC12C5XX  
7.0.2  
SERIAL CLOCK  
7.1.4  
DATA VALID (D)  
This SCL input is used to synchronize the data transfer  
from and to the device.  
The state of the data line represents valid data when,  
after a START condition, the data line is stable for the  
duration of the HIGH period of the clock signal.  
7.1  
BUS CHARACTERISTICS  
The data on the line must be changed during the LOW  
period of the clock signal. There is one bit of data per  
clock pulse.  
The following bus protocol is to be used with the  
EEPROM data memory.  
Each data transfer is initiated with a START condition  
and terminated with a STOP condition. The number of  
the data bytes transferred between the START and  
STOP conditions is determined by the master device  
and is theoretically unlimited.  
• Data transfer may be initiated only when the bus  
is not busy.  
During data transfer, the data line must remain stable  
whenever the clock line is HIGH. Changes in the data  
line while the clock line is HIGH will be interpreted as a  
START or STOP condition.  
7.1.5  
ACKNOWLEDGE  
Accordingly, the following bus conditions have been  
defined (Figure 7-3).  
Each receiving device, when addressed, is obliged to  
generate an acknowledge after the reception of each  
byte. The master device must generate an extra clock  
pulse which is associated with this acknowledge bit.  
7.1.1  
Both data and clock lines remain HIGH.  
7.1.2 START DATA TRANSFER (B)  
BUS NOT BUSY (A)  
Note: Acknowledge bits are not generated if an  
internal programming cycle is in progress.  
The device that acknowledges has to pull down the  
SDA line during the acknowledge clock pulse in such a  
way that the SDA line is stable LOW during the HIGH  
period of the acknowledge related clock pulse. Of  
course, setup and hold times must be taken into  
account. A master must signal an end of data to the  
slave by not generating an acknowledge bit on the last  
byte that has been clocked out of the slave. In this case,  
the slave must leave the data line HIGH to enable the  
master to generate the STOP condition (Figure 7-4).  
A HIGH to LOW transition of the SDA line while the  
clock (SCL) is HIGH determines a START condition. All  
commands must be preceded by a START condition.  
7.1.3  
STOP DATA TRANSFER (C)  
A LOW to HIGH transition of the SDA line while the  
clock (SCL) is HIGH determines a STOP condition. All  
operations must be ended with a STOP condition.  
1999 Microchip Technology Inc.  
DS40139E-page 31  
 复制成功!