ML2281, ML2282, ML2284, ML2288  
PIN DESCRIPTION  
NAME  
FUNCTION  
NAME  
FUNCTION  
V
Positive supply. 5V ± 10%  
DO  
Data out. Digital output which contains result  
of A/D conversion. The serial data is clocked  
out on falling edges of CLK.  
CC  
DGND  
AGND  
CH0-7,  
Digital ground. 0 volts. All digital inputs and  
outputs are referenced to this point.  
SARS  
CLK  
Successive approximation register status.  
Digital output which indicates that a  
conversion is in progress. When SARS goes  
to 1, the sampling window is closed and  
conversion begins. When SARS goes to 0,  
conversion is completed. When CS = 1, SARS  
is in high impedance state.  
Analog ground. The negative reference voltage  
for A/D converter.  
Analog inputs. Digitally selected to be single  
V +, V – ended (V ) or; V + or V – of a differential  
IN  
IN  
IN  
IN  
IN  
input. Analog range = GND - V - V  
.
IN  
CC  
COM  
Common reference point for analog inputs.  
A/D conversion is performed on voltage  
difference between analog input and this  
common reference point if single-end  
conversion is specified.  
Clock. Digital input which clocks data in on  
DI on rising edges and out on DO on falling  
edges. Also used to generate clocks for A/D  
conversion.  
DI  
Data input. Digital input which contains serial  
data to program the MUX and channel  
assignments.  
V
Reference. The positive reference voltage for  
A/D converter.  
REF  
SE  
Shift enable. Input controls whether LSB first  
bit stream is shifted out on serial output DO.  
If SE = 1, MSB first is shifted out only. If SE = 0,  
an MSB first bit stream is shifted out, then a  
second bit stream with LSB first is shifted out  
after end of conversion.  
CS  
Chip select. Selects the chip for multiplexer  
and channel assignment and A/D conversion.  
When CS = 1, all digital outputs are in high  
impedance state. When CS = 0, normal A./D  
conversion takes place.  
V+  
Input to the Shunt Regulator.  
3