ML2008, ML2009
ELECTRICAL CHARACTERISTICS (Continued)
SYMBOL
PARAMETER
NOTES
CONDITIONS
MIN
TYP
MAX
UNITS
NOTE 3
Digital and DC
VIL
VIH
IIN
Digital Input Low Voltage
Digital Input High Voltage
Input Current, Low
4
4
4
4
4
0.8
V
V
2.0
VIH = GND
VIH = VCC
–10
10
4
µA
µA
mA
IIN
Input Current, High
ICC
VCC Supply Current
No output load, VIL = GND,
VIH = VCC, VIN = 0
ISS
VSS Supply Current
4
4
4
No output load, VIL = GND,
VIH = VCC, VIN = 0
–4
0.5
mA
mA
mA
ICCP
ISSP
VCC Supply Current, ML2008
Powerdown Mode Only
No output load, VIL = GND,
VIH = VCC
VSS Supply Current, ML2008
Powerdown Mode Only
No output load, VIL = GND,
VIH = VCC
–0.1
AC Characteristics
tSET
VOUT Settling Time
4
4
VIN = 0.185V. Change gain from –24
to +24dB. Measure from WR rising
edge to when VOUT settles to within
0.05dB of final value.
20
20
µs
µs
tSTEP
VOUT Step Response
Gain = +24dB. VIN = –3V to +3V step.
Measure from VIN = –3V to when VOUT
settles to within 0.05dB of final value.
tDS
Data Setup Time
Data Hold Time
A0 Setup Time
A0 Hold Time
4
4
4
4
4
4
4
50
50
0
ns
ns
ns
ns
ns
ns
ns
tDH
tAS
tAH
tCSS
tCSH
tPW
0
CS* Setup Time
CS* Hold Time
WR* Pulse Width
0
0
50
Note 1: Absolute maximum ratings are limits beyond which the life of the integrated circuit may be impaired. All voltages unless otherwise specified are measured with
respect to ground.
Note 2: 0°C to +70°C and –40°C to +85°C operating temperature range devices are 100% tested with temperature limits guaranteed by 100% testing, sampling, or by
correlation with worst-case test conditions.
Note 3: Typicals are parametric norm at 25°C.
Note 4: Parameter guaranteed and 100% production tested.
Note 5: Parameter guaranteed. Parameters not 100% tested are not in outgoing quality level calculation.
4