MIC4120/4129
Micrel, Inc.
Absolute Maximum Ratings
(Notes 1, 2 and 3)
Supply Voltage ...........................................................24V
Input Voltage ............................... V
S
+ 0.3V to GND – 5V
Input Current (V
IN
> V
S
) .......................................... 50mA
Storage Temperature............................. –65°C to +150°C
Lead Temperature (10 sec.) ................................... 300°C
ESD Rating,
Note 4
Operating Ratings
Supply Voltage .............................................. 4.5V to 20V
Junction Temperature ............................ –40°C to +125°C
Package Thermal Resistance
3x3 MLF™
(θ
JA
) ...............................................60°C/W
EPAD SOIC-8
(θ
JA
) ..........................................58°C/W
Electrical Characteristics:
>1V/µs
Symbol
INPUT
V
IH
V
IL
I
IN
V
IN
OUTPUT
V
OH
V
OL
R
O
R
O
I
PK
I
R
High Output Voltage
Low Output Voltage
Output Resistance,
Output Low
Output Resistance,
Output High
Peak Output Current
Logic 1 Input Voltage
Logic 0 Input Voltage
Input Voltage Range
Input Current
Parameter
(T
A
= 25°C with 4.5V ≤ V
S
≤ 20V unless otherwise specified. Note 3.) Input Voltage slew rate
Conditions
Min
2.4
–5
0 V ≤ V
IN
≤ V
S
See Figure 1
See Figure 1
I
OUT
= 10 mA, V
S
= 20 V
I
OUT
= 10 mA, V
S
= 20 V
V
S
= 20 V (See Figure 6)
–10
V
S
–0.025
1.4
1.5
6
200
Typ
1.9
1.5
0.8
V
S
+ 0.3
10
Max
Units
V
V
V
µA
V
0.025
5
5
V
Ω
Ω
A
mA
Latch-Up Protection
Withstand Reverse Current
Rise Time
Fall Time
Delay Time
Delay Time
SWITCHING TIME
t
R
t
F
t
D1
t
D2
Test Figure 1, C
L
= 2200 pF
Test Figure 1, C
L
= 2200 pF
Test Figure 1
Test Figure 1
12
13
45
50
30
35
30
35
75
100
75
100
3
400
20
ns
ns
ns
ns
ns
ns
ns
ns
mA
µA
V
POWER SUPPLY
I
S
V
S
Power Supply Current
Operating Input Voltage
V
IN
= 3 V
V
IN
= 0 V
0.45
60
4.5
Notes:
1. Functional operation above the absolute maximum stress ratings is not implied.
2. Static-sensitive device. Store only in conductive containers. Handling personnel and equipment should be grounded to prevent
damage from static discharge.
3. Specification for packaged product only.
4. Devices are ESD sensitive. Handling precautions recommended. Human body model: 1.5kΩ in series with 100pF.
August 2005
3
M9999-081105