MIC384
Remote Zone 1 Temperature Result Register
R E MO T E Z O N E 1 T E MP E R A T U R E R E S U L T ( T E MP 1 )
8 -B i t R e a d O n l y
D [7]
MS B
D [ 6]
bit 6
D [ 5]
bit 5
D [ 4]
bit 4
D [ 3]
bit 3
D [ 2]
bit 2
D [ 1]
bit 1
D [ 0]
LS B
Micrel
re mote z one 1 te mpe ra ture da ta from A D C *
B i ts
D [7 : 0 ]
F u n c ti o n
me a s ure d te mpe ra ture da ta for re mote
z o ne o ne *
re a d only
O p e r a ti o n
TEMP1 Power-Up Value: 0000 0000
b
= 00
h
(0°C)
†
TEMP1 Command Byte Value: 0001 0000
b
= 10
h
* Each LSB represents one degree Centigrade. The values are
in a two's complement format such that 0°C is reported as
0000 0000
b
. See "Temperature Data Format" for more details.
†
TEMP1 will contain measured temperature data for the se-
lected zone after the completion of one conversion.
Remote Zone 1 Hysteresis Register
R E MO T E Z O N E 1 T E MP E R A T U R E H Y S T E R E S I S R E G I S T E R ( T _ H Y S T 1 )
8 -B i t R e a d /W r i te
D [7]
MS B
D [ 6]
bit 6
D [ 5]
bit 5
D [ 4]
bit 4
D [ 3]
bit 3
D [ 2]
bit 2
D [ 1]
bit 1
D [ 0]
LS B
re mote z one 1 te mpe ra ture hys te re s is *
B i ts
D [7 : 0 ]
F u n c ti o n
re mote z one one te mpe ra ture hys te re s is *
re a d/write
O p e r a ti o n
T_HYST1 Power-Up Value: 0101 1100
b
= 5C
h
(+92°C)
T_HYST1 Command Byte Value: 0001 0010
b
= 12
h
* Each LSB represents one degree Centigrade. The values are
in a two's complement format such that 0°C is reported as
0000 0000
b
. See "Temperature Data Format" for more details.
Remote Zone 1 Temperature Setpoint Register
R E MO T E Z O N E 1 T E MP E R A T U R E S E T P O I N T ( T _ S E T 1 )
8 -B i t R e a d /W r i te
D [7]
MS B
D [ 6]
bit 6
D [ 5]
bit 5
D [ 4]
bit 4
D [ 3]
bit 3
D [ 2]
bit 2
D [ 1]
bit 1
D [ 0]
LS B
re mote z one 1 te mpe ra ture s e tpoint
B i ts
D [7 : 0 ]
F u n c ti o n
re mote z one one te mpe ra ture s e tpoint*
re a d/write
O p e r a ti o n
T_SET1 Power-Up Value: 0110 0001
b
= 61
h
(+97°C)
T_SET1 Command Byte Value: 0001 0011
b
= 13
h
* Each LSB represents one degree Centigrade. The values are
in a two's complement format such that 0°C is reported as
0000 0000
b
. See "Temperature Data Format" for more details.
MIC384
16