欢迎访问ic37.com |
会员登录 免费注册
发布采购

MIC384 参数 Datasheet PDF下载

MIC384图片预览
型号: MIC384
PDF下载: 下载PDF文件 查看货源
内容描述: 三区热监事高级信息 [Three-Zone Thermal Supervisor Advance Information]
分类和应用:
文件页数/大小: 21 页 / 122 K
品牌: MICREL [ MICREL SEMICONDUCTOR ]
 浏览型号MIC384的Datasheet PDF文件第10页浏览型号MIC384的Datasheet PDF文件第11页浏览型号MIC384的Datasheet PDF文件第12页浏览型号MIC384的Datasheet PDF文件第13页浏览型号MIC384的Datasheet PDF文件第15页浏览型号MIC384的Datasheet PDF文件第16页浏览型号MIC384的Datasheet PDF文件第17页浏览型号MIC384的Datasheet PDF文件第18页  
MIC384  
Micrel  
Register Set and Programmers Model  
Internal Register Set  
Name  
TEMP0  
Description  
Command Byte  
Operation  
Power-Up Default  
measured temperature,  
local zone  
(1)  
00 (0° C)  
h
00  
8-bit read only  
8-bit read/write  
8-bit read/write  
h
(2)  
00  
CONFIG  
T_HYST0  
configuration register  
01  
h
h
hysteresis setting, local  
zone  
02  
4C (+76° C)  
h
h
temperature setpoint, local  
zone  
T_SET0  
TEMP1  
03  
8-bit read/write  
51 (+81° C)  
h
h
measured temperature,  
zone 1  
(1)  
00 (0° C)  
h
10  
8-bit read only  
8-bit read/write  
8-bit read/write  
h
T_HYST1 hysteresis setting, zone 1  
12  
5C (+92° C)  
h
h
temperature setpoint,  
T_SET1  
zone 1  
13  
61 (+97° C)  
h
h
measured temperature,  
(1)  
00 (0° C)  
h
TEMP2  
zone 2  
20h  
22h  
23h  
8-bit read only  
8-bit read/write  
8-bit read/write  
T_HYST2 hysteresis setting, zone 2  
5C (+92° C)  
h
temperature setpoint,  
T_SET2  
zone 2  
61 (+97° C)  
h
(1) TEMPx will contain measured temperature data after the completion of one conversion cycle.  
(2) After the first Fault_Queue conversions are complete, status bits will be set if TEMPx > T_SETx.  
Detailed Register Descriptions  
Configuration Register  
CONFIGURATION REGISTER (CONFIG)  
8-Bit Read/Write  
D[7]  
D[6]  
D[5]  
D[4]  
D[3]  
D[2]  
D[1]  
D[0]  
read only read only read only  
read/write  
read/write read/write read/write  
zone 0  
status  
(S0)  
zone 1  
status  
(S1)  
zone 2  
status  
(S2)  
fault queue  
depth  
(FQ[1:0])  
interrupt CMP/INT  
Shutdown  
mask  
(IM)  
mode  
(SHDN)  
(MODE)  
Bits  
S0  
Function  
Operation  
local interrupt status (read only)  
1 = event occured, 0 = no event  
1 = event occured, 0 = no event  
1 = event occured, 0 = no event  
S1  
remote zone 1 interrupt status (read only)  
remote zone 2 interrupt status (read only)  
S2  
00 = 1 conversion, 01 = 2 conversions,  
10 = 4 conversions, 11 = 6 conversions  
FQ[1:0] Fault_Queue depth  
IM  
interrupt mask  
1 = disabled, 0 = interrupts enabled  
comparator/interrupt  
mode selection for /INT pin  
1 = interrupt mode,  
0 = comparator mode  
MODE  
normal/shutdown  
operating mode selection  
1 = shutdown,  
0 = normal  
SHDN  
(*)  
CONFIG Power-Up Value: 0000 0000 = 00  
b
h
not in shutdown mode  
comparator mode  
Fault_Queue depth = 1  
interrupts enabled.  
no temperature events pending  
CONFIG Command Byte Value: 0000 0001 = 01  
b
h
* Following the first Fault_Queue conversions, one or more of the status bits may be set.  
MIC384  
14  
September 2000