Micrel, Inc.  
MIC2786/MIC2787  
Electrical Characteristics (4) (Continued)  
VIN = 3.0V, TA = 25°C, Bold values indicate 40°C TA +85°C; unless noted otherwise.  
Parameter  
Conditions  
A, B  
Min.  
Typ.  
0.5  
Max.  
Units  
%
Hysteresis Voltage (VHYST  
Hysteresis Voltage (VHYST  
Reset Time  
)
)
C, D, E, F, G, H  
1.0  
%
PDY = Open  
PDY = 0V  
PDY = VIN  
Option X  
1.6  
3.2  
4.8  
140  
240  
2.0  
4.0  
6.0  
220  
350  
2.4  
4.8  
7.2  
280  
480  
s
s
Setup Delay (tSETUP  
)
s
ms  
ms  
Reset Timeout Delay (tRESET  
)
Option Y  
Reset Outputs (/RST, RSTP)  
0.3  
0.3  
0.3  
VIN = 4.5V, ISINK = 3.2mA  
VIN = 3.3V, ISINK = 2.5mA  
VIN = 1.6V, ISINK = 1.0mA  
VIN = 4.5V, ISOURCE = 0.8mA  
VIN = 2.7V, ISOURCE = 0.5mA  
VIN = 1.6V, ISOURCE = 250μA  
V/RST = 5.5V  
Reset Output Voltage Low  
(/RST Output and RSTP Output) (VOL  
V
)
0.8 × VIN  
0.8 × VIN  
0.8 × VIN  
Reset Output Voltage High  
V
(RSTP Output) (VOH  
)
/RST Output Leakage (ILO  
)
0.3  
μA  
Manual Reset Inputs (/MR0, /MR1)  
Input High Voltage (VIH)  
1.2  
V
V
Input Low Voltage (VIL)  
0.3  
1.0  
Internal Pull-Up Resistor (RPU  
Leakage Current /MR0, /MR1 Pin (IMR  
Programmable Setup Delay Input (PDY)  
)
MIC2786 only  
65  
kΩ  
μA  
)
/MR0, /MR1 inputs; MIC2787 only  
1.0  
PDY = VIN, /MR0 = /MR1 = 0V  
PDY = VIN, /MR0 = VIN or /MR1= VIN  
PDY = 0V, /MR0 = /MR1 = 0V  
+60  
100  
-60  
μA  
nA  
μA  
nA  
Input Bias Current PDY Pin (IPDY  
)
PDY = 0V, /MR0 = VIN or /MR1 = VIN  
100  
Notes:  
1. Exceeding the absolute maximum rating may damage the device.  
2. The device is not guaranteed to function outside its operating rating.  
3. Devices are ESD sensitive. Handling precautions recommended. Human body model, 1.5kin series with 100pF.  