Micrel, Inc.  
MIC2544A/2548A  
Giving one a maximum ILIMIT variation over-temperature  
of:  
Setting ILIMIT  
The MIC2544A/2548A’s current limit is user  
programmable and controlled by a resistor connected  
between the ILIMIT pin and ground. The value of this  
resistor is determined by the following equation:  
ILIMIT_MIN  
ILIMIT_TYP  
1.0A  
ILIMIT_MAX  
0.79A (-21%)  
1.19A (+19%)  
CurrentLimitFactor(CLF)  
ILIMIT  
=
RSET  
or  
I_OUT  
0.2  
0.3  
0.4  
0.5  
0.6  
0.7  
0.8  
0.9  
1
R_SET  
I_OUT_Min  
I_OUT_Max  
0.260  
0.390  
0.520  
0.650  
0.720  
0.840  
0.960  
1.080  
1.200  
1.320  
1.440  
1.560  
1.680  
1.800  
1150  
767  
575  
460  
383  
329  
288  
256  
230  
209  
192  
177  
164  
153  
0.140  
0.210  
0.280  
0.350  
0.480  
0.560  
0.640  
0.720  
0.800  
0.880  
0.960  
1.040  
1.120  
1.200  
CurrentLimitFactor(V)  
ILIMIT (A)  
RSET  
=
For example: Set ILIMIT = 1.0A  
Looking in the Electrical specifications we will find CLF  
at ILIMIT = 1 A.  
Min  
Typ  
Max  
Units  
184  
230  
276  
V
1.1  
1.2  
1.3  
1.4  
1.5  
Table 1. CLF at ILIMIT = 1A  
For the sake of this example, we will say the typical  
value of CLF at an IOUT of 1A is 230V. Applying the  
equation above:  
230V  
RSET(Ω) =  
= 230Ω  
1.0A  
Table 2. MIC2544A/2548A RSET Table  
R
SET = 232  
(the closest standard 1% value)  
Designers should be aware that variations in the  
measured ILIMIT for a given RSET resistor, will occur  
because of small differences between individual ICs  
(inherent in silicon processing) resulting in a spread of  
Short-Circuit Protection  
In the event of a short circuit, the output current will fold  
back to approximately 70% of the short-circuit current-  
limit.  
ILIMIT values. In the example above a typical value of CLF  
was used to calculate RSET. One can determine ILIMIT’s  
spread by using the minimum and maximum values of  
Fault Flag  
FLG is an N-channel, open-drain MOSFET output. The  
fault flag is active (low) for current-limit or thermal  
shutdown conditions. The flag output MOSFET is  
capable of sinking a 10mA load to typically 100mV  
above ground. The FLG response delay time tD is  
CLF and the calculated value of RSET  
.
184V  
ILIMIT_MIN  
=
= 0.79A  
232Ω  
276V  
ILIMIT _ MAX  
=
= 1.19A  
232Ω  
typically 5µs.  
M9999-043010  
April 2010  
15