Selection of Isolation Transformer
A 1:1 isolation transformer is required at the line interface. An isolation transformer with integrated common-mode chokes
is recommended for exceeding FCC requirements.
The following table gives recommended transformer characteristics.
Parameter
Value
Test Condition
Turns ratio
1 CT : 1 CT
350µH
0.4µH
Open-circuit inductance (min.)
Leakage inductance (max.)
Inter-winding capacitance (max.)
D.C. resistance (max.)
Insertion loss (max.)
HIPOT (min.)
100mV, 100kHz, 8mA
1MHz (min.)
12pF
0.9Ω
1.0dB
0MHz – 65MHz
1500Vrms
Table 15. Transformer Selection Criteria
Magnetic Manufacturer
Bel Fuse
Part Number
S558-5999-U7
SI-46001
SI-50170
LF8505
Auto MDI-X
Yes
Number of Port
1
1
1
1
1
1
1
1
1
Bel Fuse (Mag Jack)
Bel Fuse (Mag Jack)
Delta
Yes
Yes
Yes
LanKom
LF-H41S
H1102
Yes
Pulse
Yes
Pulse (low cost)
Transpower
H1260
Yes
HB726
Yes
TDK (Mag Jack)
TLA-6T718
Yes
Table 16. Qualified Single Port Magnetics
Selection of Reference Crystal
Characteristics
Value
Units
MHz
ppm
pF
Frequency
25
Frequency tolerance (max)
Load capacitance (max)
Series resistance
±50
20
40
Ω
Table 17. Typical Reference Crystal Characteristics