TXRX_982_R1 Evaluation Board  
12. In OEM Configuration Register 0 window,  
set ENABLE/DISABLE to DISABLE, VMOD  
REFERENCE to GND, and temperature  
zone to INTERNAL.  
Set-Up and Operation  
Follow the step-by-step procedure to set-up the board  
safely and properly:  
1. Connect the on board DB-25 connector to the  
parallel port of a computer.  
13. In OEM Configuration Register 1 window:  
a. Set APC OP-AMP TYPE to COMMON  
EMITTER.  
Note: Set the selection bit to 0, 0 should correspond  
to EMITTER FOLLOWER, which should be displayed  
on the bottom and COMMON EMITTER on the top.  
2. Connect the differential input of the laser  
driver to DATA output of the pattern generator.  
3. Use a multimode fiber jumper, with  
appropriate connectors to connect optical  
output of the VCSEL to a VOA (variable  
optical attenuator) preset to 0dB attenuation.  
b. Select the voltage to report in  
VINH:VINL.  
4. Connect the output of the VOA to the optical  
input of the DCA, power-meter, or optical to  
electrical converter.  
c. Set Feedback voltage source to 1.22V.  
d. Set FEEDBACK BIAS REF and RES  
TERMINATION to GND and VBIAS  
DRIVE to SOURCE (NPN). Set  
5. Pre-adjust the power supply to 3.3V and turn it  
off. Connect TP3 to VCC (3.3V) and TP5 to  
GND, then turn the power supply ON. The  
total current drawn from the power supply  
should be less than 300mA.  
INTERNAL FEEDBACK RESISTOR to  
an arbitrary value (1.6K for example).  
e. Set FEEDBACK BIAS REF and RES  
TERMINATION to GND and VBIAS  
DRIVE to SOURCE (NPN).  
6. Launch the MIC3000/1 software. The  
MIC3001 Optical Transceiver Management  
IC panel opens with Panels and Help grayed  
out and only Utilities can be run.  
f. Set INTERNAL FEEDBACK  
RESISTOR to arbitrary value (1.6K for  
example).  
7. Refer to MIC3000/1 Software User’s Guide for  
the detailed settings.  
14. In OEM Configuration Register 2, the  
MIC3001 address and look-up table offset can  
be modified. The look-up table covers 128°C.  
The temperature range for offset = 0 is 0° to  
+127°C.) This range can be shifted down by  
2x the value. The offset is set to. If offset = 15,  
the temperature range becomes –30° to  
+97°C.  
8. On the main window select Utilities to open  
the utilities panel, then select SCAN to read  
the address of the MIC3001 and GET to read  
the manufacturer ID, Device ID, and Die  
Revision. If there is a failure in reading one of  
these parameters, you cannot proceed further.  
If all the parameters are read correctly, close  
the Utilities window to return to the main  
window where Panels and Help are no longer  
grayed out.  
15. In OEM Configuration Register 0 window,  
set ENABLE/DISABLE to ENABLE.  
16. On Panels list select OEM CONFIG 3-4 and  
select EXTERNAL CALIBRATION (default  
setting), LOS COMPARATOR ENABLE,  
SHDN, RXLUT INPUT TEMPERATURE, and  
RSOUT. If needed, later set ISTART to a  
different value to speed up the APC loop  
during laser turn ON after a FAULT  
9. Select Panels to display the list of setting  
panels.  
10. All the bits displayed on the panels can be  
read and/or modified on the panels or by  
accessing the registers directly by selecting  
ALL REGISTERS, enter the serial address,  
the register address, select GET to read the  
content or type a value and select SET NEW  
to write. In this procedure the bits are set on  
the panels.  
occurrence. Close the window to return to  
main window.  
17. On Panels list, select External Calibration.  
Set all the offsets to 0 and slopes to 1. Set  
RX_PWR(1) to 1. These parameters might  
need to be changed later to correct the  
measured values (calibration). Return to the  
main window.  
11. Select OEM CONFIG 0-2 to open the OEM  
configuration registers 0, 1, and 2 windows.  
3