WE128K32-XXX
ABSOLUTE MAXIMUM RATINGS
TRUTH TABLE
Parameter
Operating Temperature
Storage Temperature
Signal Voltage Relative to GND
Voltage on OE# and A9
Symbol
TA
TSTG
VG
Unit
°C
°C
V
CS#
H
OE#
X
WE#
X
Mode
Standby
Read
Data I/O
High Z
-55 to +125
-65 to +150
-0.6 to + 6.25
-0.6 to +13.5
L
L
H
Data Out
L
H
L
Write
Data In
V
X
H
X
Out Disable
Write
High Z/Data Out
NOTE:
X
X
H
Stresses above those listed under "Absolute Maximum Ratings" may cause permanent damage to
the device. This is a stress rating only and functional operation of the device at these or any other
conditions above those indicated in the operational sections of this specification is not implied.
Exposure to absolute maximum rating conditions for extended periods may affect device reliability.
X
L
X
Inhibit
CAPACITANCE
TA = +25°C
RECOMMENDED OPERATING CONDITIONS
Parameter
Symbol
COE
Conditions
Max Unit
OE# capacitance
VIN = 0 V, f = 1.0 MHz
VIN = 0 V, f = 1.0 MHz
50
pF
pF
Parameter
Supply Voltage
Symbol
VCC
VIH
Min
4.5
2.0
-0.5
-55
-40
Max
5.5
Unit
V
V
V
°C
°C
WE1-4# capacitance
HIP (PGA)
CWE
20
20
20
20
50
Input High Voltage
Input Low Voltage
VCC + 0.3
+0.8
CQFP G2T
VIL
Operating Temp. (Mil.)
Operating Temp. (Ind.)
TA
TA
+125
+85
CS1-4# capacitance
Data I/O capacitance
Address input capacitance
CCS
CI/O
CAD
VIN = 0 V, f = 1.0 MHz
VI/O = 0 V, f = 1.0 MHz
VIN = 0 V, f = 1.0 MHz
pF
pF
pF
This parameter is guaranteed by design but not tested.
DC CHARACTERISTICS
VCC = 5.0V, GND = 0V, -55°C ≤ TA ≤ +125°C
Conditions
Parameter
Input Leakage Current
Output Leakage Current
Operating Supply Current (x32)
Standby Current
Symbol
Min
Max
10
10
250
2.5
0.45
Unit
ILI
VCC = 5.5, VIN = GND to VCC
μA
μA
mA
mA
V
ILOx32
ICCx32
ISB
CS# = VIH, OE# = VIH, VOUT = GND to VCC
CS# = VIL, OE# = VIH, f = 5MHz
CS# = VIH, OE# = VIH, f = 5MHz
IOL = 2.1mA, VCC = 4.5V
Output Low Voltage
VOL
Output High Voltage
VOH
IOH = -400μA, VCC = 4.5V
2.4
V
NOTE: DC test conditions: VIH = VCC -0.3V, VIL = 0.3V
FIGURE 3 AC TEST CIRCUIT
AC TEST CONDITIONS
Parameter
Typ
Unit
V
Input Pulse Levels
VIL = 0, VIH = 3.0
Input Rise and Fall
5
ns
V
I
OL
Input and Output Reference Level
Output Timing Reference Level
Notes: VZ is programmable from -2V to +7V.
1.5
1.5
Current Source
V
I
OL & IOH programmable from 0 to 16mA.
Tester Impedance Z0 = 75Ω.
Z is typically the midpoint of VOH and VOL
OL & IOH are adjusted to simulate a typical resistive load circuit.
ATE tester includes jig capacitance.
V
~ 1.5V
~
z
D.U.T
= 50 pf
Bipolar Supply
C
eff
V
I
.
I
OH
Current Source
3
4315.19E-0718-ss-WE128K32-XXX
Mercury Corp. - Memory and Storage Solutions • (602) 437-1520 • www.mrcy.com