Differential PECL Crystal Clock Oscillators
3HPF5762 Series
+3.3V “F” family
3HPF5762
features 0.4 ps typical phase jitter and
low phase noise (-132 dBc at 10 KHz for 155.520 MHz).
Differential PECL Outputs meet the requirements for
SONET, XDSL and other communication protocols.
General Specifications
Product Series
Frequency Range
Output Logic
Frequency Stability
vs Operating Temperature
Range
PECL Outputs
MERCURY
Since 1973
3HPF5762; “F” family characteristics. Tri-State on pad 2
38 MHz ~ 640 MHz.
Differential PECL 100 K square wave
Commercial “ C ”::
Industrial
“
I
”:
Stability Code
-10°C to +70°C
-40°C to +85°C
±25 ppm
A
D
±50 ppm
B
E
±100 ppm
C
F
Custom ±xx ppm
Cxx
Ixx
If custom, use “temperature range code + desired ppm stability” for the stability
code. Example: “C20” (±20 ppm over -10 to +70°C) or “I35”.
±3 ppm max.with ±10% supply voltage change
±2 ppm max.with ±10% Load change:
+3.3 V ± 10 %
2.275 V min.; 2.420 V max. Condition: 50 ohms to V
DD
-2V
1.490 V min..; 1.680 V max. Condition: 50 ohms to V
DD
-2V
38 MHz≤ fout
≤
100 MHz: 70 mA max.
100 MHz< fout
≤
320 MHz: 85 mA max
320 MHz< fout
≤
640 MHz: 95 mA max
50 ohms into V
CC
-2V or Thevenin equivalent (terminating resistors required on all
outputs).
fout < 150 MHz: 0.5 ns typical; 0.7 ns max.
150 MHz
≤
fout
≤
320 MHz: 0.4 ns. typical; 0.55 ns. max
f320 MHz < fout
≤
640 MHz: 0.3 ns. typical; 0.45 ns. max
Measured at 20%
↔
80% of the wave form.
50% ± 5% max. measured at 50% waveform
Differential PECL and complimentary PECL outputs.
Both outputs are disabled (high impedance) when pad No. 2 is taken
below 0.45*Vcc referenced to ground (threshold). Oscillator is always
ON. Only buffer stage is disabled.
Disable current: 50 uA max. (at 0.0 V).
Disable time: 10 ns max.
At disabled mode, both outputs are enabled when pad No. 2 is taken
above 0.45*Vcc referenced to ground (threshold).
Enable time: 10ns+one period of the output frequency max.
0.5 ps max. (12 KHz to 20 MHz integrated)
10 Hz
100 Hz
1 kHz
10 kHz
100 kHz
1 MHz
10 MHz
-65
-96
-124
-136
-132
-145
-149
-66
-96
-122
-132
-126
-144
-150
vs Supply Voltage Change
vs Load Change
Supply Voltage V
CC
Output Voltage HIGH “1”, V
OH
Output Voltage LOW “0”, V
OL
Current Consumption
Load
Rise Time (Tr) and
Fall Time (Tf)
Duty Cycle
No Connection
Tri-state
Function on
pad No. 2
Disable
Enable
Phase Jitter (RMS)
SSB Phase
Offset
Noise (dBc/Hz)
77.760 MHz
106.250 MHz
Taiwan: TEL (886)-2-2406-2779, FAX (886)-2-2496-0769, e-mail: sales-tw@mercury-crystal.com
U.S.A.: TEL (1)-909-466-0427, FAX (1)-909-466-0762, e-mail:
sales-us@mercury-crystal.com
MERCURY
Page 1 of 4
Date: April 1, 2008
Rev. 1
MERCURY