General Specifications
TA=+25°C, at specified voltage, CL=15 pF
Product Series
G576
V
DD = +3.3 V D.C. ±10%
Voltage code is“3”
VDD = +5.0 V D.C. ±10%
Voltage code is “5”
Input Voltage (VDD)
Frequency Range
Circuit Design
Package Type
0.625 MHz ~ 45 MHz
1.25MHz ~ 55.2 MHz
Fundamental mode crystal used. No PLL.
6 pad ceramic leadless SMD. 5x7x1.8 mm.
To tune to the nominal frequency
with control voltage Vc = 1.65V±0.2V with control voltage Vc =2.5V±0.2V
To tune to the nominal frequency
Initial Frequency Accuracy (at+25°C)
Output Voltage HIGH “1”
Output Voltage LOW “0”
Frequency Stability(1)
Commercial Temperature Range
(code “C”)
90% of VDD min.
10% of VDD max.
“A”: ±25 ppm over 0°C to +70°C
“B”:±50 ppm over 0°C to +70°C
“C”:±100 ppm over 0°C to +70°C
For non-standard please specify desired frequency stability after the “C”.
For example “C20” is ±20 ppm over 0 to +70°C
“D”:±25 ppm over -40°C to +85°C
“E”:±50 ppm over -40°C to +85°C
Industrial Temperature Range
(code “I”)
“F”:±100 ppm over -40°C to +85°C
For non-standard please specify desired frequency stability after the “I”.
For example “
10 mA max.
15 pF
I
20” is ±20 ppm over -40 to +85°C
15 mA max.
Current Consumption
Output Load
10 n Sec. max; 4 n Sec. typical.
Rise Time (Tr) and Fall Time (Tf)
Measured between 20% and 80% of the wave form.
45% min. 55 % max. (measured at 50% of wave form)
10 m Sec. max. 3 m Sec. typical
Duty Cycle
Start-up Time (Ts)
Control Voltage Range
Control Voltage Center (Vc)
+0.3 V to +3.0 V
+1.65 V
From ±30 ppm to ±120 ppm.
To define the deviation range please use
“N” for minimum (no less than the deviation specified);
“M” for maximum (no more than the deviation specified)
“T” for typical (±20% of the range specified).
10% max.; 6% typical
+0.5 V to +4.5 V
+2.5 V
From ±30 ppm to ±150 ppm.
Frequency Deviation Range
Linearity
Slope Polarity
(Transfer Function)
Positive: Increasing control voltage increases output frequency.
10 kHz min. measured at -3 dB with Vcon=1.65V for 3G576 and
Vcon=2.5V for 5G576
1 MΩ. typical
Modulation Bandwidth
Input Impedance
Output is enabled when no connection or ≥1.6 V is applied to pad 2 or pad 5
Output is disabled and high impedance when ≤0.55 V is applied to pad 2 or
pad 5. Pad 2 and pad 5 are internally connected.
Tri-State Control
Characteristics
Aging
±5 ppm per year max.
Offset
dBc/Hz
10 Hz
-70
100 Hz
-105
1 KHz
-132
10 KHz
-142
100 KHz
-145
1 MHz
-150
Phase Noise
Integrated Phase Jitter
Period Jitter – RMS
Period Jitter – peak to peak
Packaging
1 ps max. 12 KHz ~20 MHz
2 ps typical
14 ps typical
180 mm reel, 16 mm tape, 1000 pcs per reel.
(1)Inclusive of 25°C calibration tolerance, stability over operating temperature range, ±10% supply voltage variation,
±10% load variation, aging, shock and vibration.
MERCURY
Page 2 of 3
Date: Oct.1, 2006
Rev. 0