欢迎访问ic37.com |
会员登录 免费注册
发布采购

3G576A-120M-0.625 参数 Datasheet PDF下载

3G576A-120M-0.625图片预览
型号: 3G576A-120M-0.625
PDF下载: 下载PDF文件 查看货源
内容描述: [Oscillator]
分类和应用:
文件页数/大小: 3 页 / 128 K
品牌: MERCURY [ MERCURY UNITED ELECTRONICS INC ]
 浏览型号3G576A-120M-0.625的Datasheet PDF文件第1页浏览型号3G576A-120M-0.625的Datasheet PDF文件第3页  
General Specifications  
TA=+25°C, at specified voltage, CL=15 pF  
Product Series  
G576  
V
DD = +3.3 V D.C. ±10%  
Voltage code is“3”  
VDD = +5.0 V D.C. ±10%  
Voltage code is “5”  
Input Voltage (VDD)  
Frequency Range  
Circuit Design  
Package Type  
0.625 MHz ~ 45 MHz  
1.25MHz ~ 55.2 MHz  
Fundamental mode crystal used. No PLL.  
6 pad ceramic leadless SMD. 5x7x1.8 mm.  
To tune to the nominal frequency  
with control voltage Vc = 1.65V±0.2V with control voltage Vc =2.5V±0.2V  
To tune to the nominal frequency  
Initial Frequency Accuracy (at+25°C)  
Output Voltage HIGH “1”  
Output Voltage LOW “0”  
Frequency Stability(1)  
Commercial Temperature Range  
(code “C”)  
90% of VDD min.  
10% of VDD max.  
A”: ±25 ppm over 0°C to +70°C  
B”:±50 ppm over 0°C to +70°C  
C”:±100 ppm over 0°C to +70°C  
For non-standard please specify desired frequency stability after the “C”.  
For example “C20” is ±20 ppm over 0 to +70°C  
D”:±25 ppm over -40°C to +85°C  
E”:±50 ppm over -40°C to +85°C  
Industrial Temperature Range  
(code “I”)  
F”:±100 ppm over -40°C to +85°C  
For non-standard please specify desired frequency stability after the “I”.  
For example “  
10 mA max.  
15 pF  
I
20” is ±20 ppm over -40 to +85°C  
15 mA max.  
Current Consumption  
Output Load  
10 n Sec. max; 4 n Sec. typical.  
Rise Time (Tr) and Fall Time (Tf)  
Measured between 20% and 80% of the wave form.  
45% min. 55 % max. (measured at 50% of wave form)  
10 m Sec. max. 3 m Sec. typical  
Duty Cycle  
Start-up Time (Ts)  
Control Voltage Range  
Control Voltage Center (Vc)  
+0.3 V to +3.0 V  
+1.65 V  
From ±30 ppm to ±120 ppm.  
To define the deviation range please use  
N” for minimum (no less than the deviation specified);  
M” for maximum (no more than the deviation specified)  
T” for typical (±20% of the range specified).  
10% max.; 6% typical  
+0.5 V to +4.5 V  
+2.5 V  
From ±30 ppm to ±150 ppm.  
Frequency Deviation Range  
Linearity  
Slope Polarity  
(Transfer Function)  
Positive: Increasing control voltage increases output frequency.  
10 kHz min. measured at -3 dB with Vcon=1.65V for 3G576 and  
Vcon=2.5V for 5G576  
1 M. typical  
Modulation Bandwidth  
Input Impedance  
Output is enabled when no connection or 1.6 V is applied to pad 2 or pad 5  
Output is disabled and high impedance when 0.55 V is applied to pad 2 or  
pad 5. Pad 2 and pad 5 are internally connected.  
Tri-State Control  
Characteristics  
Aging  
±5 ppm per year max.  
Offset  
dBc/Hz  
10 Hz  
-70  
100 Hz  
-105  
1 KHz  
-132  
10 KHz  
-142  
100 KHz  
-145  
1 MHz  
-150  
Phase Noise  
Integrated Phase Jitter  
Period Jitter – RMS  
Period Jitter – peak to peak  
Packaging  
1 ps max. 12 KHz ~20 MHz  
2 ps typical  
14 ps typical  
180 mm reel, 16 mm tape, 1000 pcs per reel.  
(1)Inclusive of 25°C calibration tolerance, stability over operating temperature range, ±10% supply voltage variation,  
±10% load variation, aging, shock and vibration.  
MERCURY  
Page 2 of 3  
Date: Oct.1, 2006  
Rev. 0