 浏览型号MLX90614ESF-DBB的Datasheet PDF文件第12页浏览型号MLX90614ESF-DBB的Datasheet PDF文件第13页浏览型号MLX90614ESF-DBB的Datasheet PDF文件第14页浏览型号MLX90614ESF-DBB的Datasheet PDF文件第15页浏览型号MLX90614ESF-DBB的Datasheet PDF文件第17页浏览型号MLX90614ESF-DBB的Datasheet PDF文件第18页浏览型号MLX90614ESF-DBB的Datasheet PDF文件第19页浏览型号MLX90614ESF-DBB的Datasheet PDF文件第20页  
MLX90614 family  
Single and Dual Zone  
Infra Red Thermometer in TO-39  
The indexes MD and SD for the latest timings are used – MD when the master device is making  
acknowledge; SD when the slave device is making acknowledge-. For other timings see [1].  
Tsuac  
Thdac  
Timeout,L  
Timeout,H  
SCL  
PWM/SDA  
Figure 7: SMBus timing  
8.4.5 Bit transfer  
Changing  
data  
Sampling  
data  
SCL  
PWM/SDA  
Figure 8: Bit transfer on SMBus  
The data on PWM/SDA must be changed when SCL is low (min 300ns after the falling edge of SCL). The  
data is fetched by both MD and SDs on the rising edge of the SCL.  
8.4.6 Commands  
RAM and EEPROM can be read both with 32x16 sizes. If the RAM is read, the data are divided by two, due  
to a sign bit in RAM (for example, TOBJ1 - RAM address 0x07h will sweep between 0x27ADh to 0x7FFF as the  
object temperature rises from -70.01°C to +382.19°C). The MSB read from RAM is an error flag (active high)  
for the linearized temperatures (TOBJ1, TOBJ2 and Ta). The MSB for the raw data (e.g. IR sensor1 data) is a sign  
bit (sign and magnitude format). A write of 0x0000 must be done prior to writing in EEPROM in order to erase  
the EEPROM cell content. Refer to EEPROM detailed description for factory calibration EEPROM locations  
that need to be kept unaltered.  
Opcode  
Command  
000x xxxx*  
001x xxxx*  
1111_0000**  
1111_1111  
RAM Access  
EEPROM Access  
Read Flags  
Enter SLEEP mode  
Note*: The xxxxx represent the 5 LSBits of the memory map address to be read/written.  
Note**: Behaves like read command. The MLX90614 returns PEC after 16 bits data of which only 4 are  
meaningful and if the MD wants it, it can stop the communication after the first byte. The difference between  
read and read flags is that the latter does not have a repeated start bit.  
Flags read are:  
Data[15] – EEBUSY – the previous write/erase EEPROM access is still in progress. High active.  
Data[14] – Unused  
Data[13] - EE_DEAD – EEPROM double error has occurred. High active.  
Data[12] – INIT – POR initialization routine is still ongoing. Low active.  
Data[11] – not implemented.  
Data[10..0] – all zeros.  
Flags read is a diagnostic feature. The MLX90614 can be used regardless of these flags.  
3901090614  
Rev 003  
Page 16 of 40  
Data Sheet  
03/Oct/2007