MLX90255-BA
Linear Optical Array
3. MLX90255BA Electrical Specifications
DC Operating Parameters TA = -40oC to 125oC, VDD = 4.5V to 5.5V (unless otherwise specified)
Parameter
Symbol
Test Conditions
Min
Typ
Max
Units
Supplyꢀvoltageꢀ
Vddꢀ
Viꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
4.5ꢀ
5ꢀ
ꢀ
5.5ꢀ
Vꢀ
Vꢀ
Inputꢀvoltageꢀ
0ꢀ
Vdd*0.7ꢀ
0ꢀ
Vddꢀ
Vddꢀ
Highꢁlevelꢀinputꢀvoltageꢀ
Lowꢁlevelꢀinputꢀvoltageꢀ
HysteresisꢀonꢀSIꢀandꢀCLKꢀ
Wavelengthꢀofꢀlightꢀsourceꢀ
Clockꢀfrequencyꢀ
Vihꢀ
Vilꢀ
ꢀ
Vꢀ
ꢀ
Vdd*0.3ꢀ
0.8ꢀ
Vꢀ
ꢀ
0.2ꢀ
0.4ꢀ
Vꢀ
ꢀ
400ꢀ
64ꢀ
ꢀ
ꢀ
ꢀ
1000ꢀ
500ꢀ
nmꢀ
Fclockꢀ
Tintꢀ
kHzꢀ
msꢀ
Sensorꢀintegrationꢀtimeꢀbelowꢀ
60°Cꢀ(1)ꢀ
0.125ꢀ
100ꢀ
ms
µs
Sensorꢀintegrationꢀtimeꢀ(fullꢀ
temperatureꢀrange)ꢀ(2)ꢀ
Tintꢀ
Tqtꢀ
ꢀ
ꢀ
0.125ꢀ
8ꢀ
ꢀ
ꢀ
2ꢀ
ꢀ
Pixelꢀchargeꢀtransferꢀtimeꢀ(fullꢀ
tempꢀrange)ꢀ
ns
Setupꢀtime,ꢀserialꢀinputꢀ
Tsu(SI)ꢀ
Th(SI)ꢀ
Taꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
350ꢀ
160ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ns
Holdꢀtime,ꢀserialꢀinputꢀ(3)ꢀ
Operatingꢀfreeꢁairꢀtemperatureꢀ
Clockꢀpulseꢀdurationꢀ(high)ꢀ
Clockꢀpulseꢀdurationꢀ(low)ꢀ
ꢀ
ꢁ40ꢀ
125ꢀ
°Cꢀ
nsꢀ
nsꢀ
Tw(H)ꢀ
Tw(L)ꢀ
1000ꢀ
1000ꢀ
ꢀ
ꢀ
Notes:
(1) Reset until clock pulse 18 (on declining flank).
Minimum integration time = (133-18) * CLK period + 10µs (this is the time the S&H cap needs to follow).
At 500kHz clock speed, the minimum integration time becomes 0.240ms.
(2) At 125°C, the integration time should be limited to 2ms.
(3) The SI pulse must go low before the rising edge of the next clock pulse.
390109025502
Rev. 008
Page 3 of 12
Nov/05