Interrupt  
There are seven interrupt sources available in MPC82x52A. Each interrupt source can be  
individually enabled or disabled by setting or clearing a bit in the SFR named IE. This register  
also contains a global disable bit (EA), which can be cleared to disable all interrupts at once.  
Each interrupt source has two corresponding bits to represent its priority. One is located in  
SFR named IPH and the other is in IP register. Higher-priority interrupt will be not interrupted  
by lower-priority interrupt request. If two interrupt requests of different priority levels are  
received simultaneously, the request of higher priority is serviced. If interrupt requests of the  
same priority level are received simultaneously, an internal polling sequence determine which  
request is serviced. The following table shows the internal polling sequence in the same  
priority level and the interrupt vector address.  
Source  
External interrupt 0  
Timer 0  
External interrupt 1  
Timer1  
Serial Port  
SPI/ADC  
PCA/LVF  
Vector address  
03H  
Priority within level  
1 (highest)  
0BH  
13H  
1BH  
23H  
2BH  
33H  
2
3
4
5
6
7
The external interrupt /INT0, and /INT1 can each be either level-activated or  
transition-activated, depending on bits IT0 and IT1 in register TCON. The flags that actually  
generate these interrupts are bits IE0 and IE1 in TCON. When an external interrupt is  
generated, the flag, that generated it, is cleared by the hardware as soon as the service  
routine is vectored to only if the interrupt was transition –activated. Then the external  
requesting source is what controls the request flag, rather than the on-chip hardware.  
The Timer0 and Timer1 interrupts are generated by TF0 and TF1, which are set by a rollover  
in their respective Timer/Counter registers in most cases. When a timer interrupt is generated,  
the flag, that generated it, is cleared by the on-chip hardware as soon as the service routine is  
vectored to.  
The serial port interrupt is generated by the logical OR of RI and TI. Neither of these flags is  
cleared by hardware when the service routine is vectored to. The service routine should poll  
RI and TI to determine which one to request service, and it will be cleared by software.  
The 2BH interrupt is shared by the logical OR of SPI interrupt and ADC interrupt. Neither of  
these flags is cleared by hardware when the service routine is vectored to. The service routine  
should poll them to determine which one to request service and it will be cleared by software.  
MEGAWIN  
MPC82x52A Data Sheet  
29