DIL Series
Sealed DIL Version w/ up to 4.25
kVDC Breakdown Voltage Option
MEDER electronic
RELAY DATA
All Data at 20° C
Contact Ratings
Switching Power
Switching Voltage
Switching Current
Carry Current
Static Contact Resistance
Dynamic Contact
Resistance
Insulation Resistance
(100 Volts applied)
Breakdown Voltage
Operate Time incl. Bounce
Release Time
Capacitance
Life Expectancies
Switching 5V - 10 mA
DC <10 pF stray cap.
1000
1000
10
6
Cycles
Switch Model
→
Contact Form
→
Conditions
Any DC combination of V & A not
to exceed their individual max.‘s.
Switch 66
Form A
Switch 72
Form A
Min. Typ. Max. Min. Typ. Max. Units
10
200
0.5
1.25
150
200
10
10
10
12
225
1.5*
15
200
1.0
1.25
150
200
10
12
10
12
250
1.5*
W
V
A
A
mΩ
mΩ
Ω
VDC
kVDC
DC or peak AC
DC or peak AC
DC or peak AC
w/ 0.5 V & 50mA
Measured w/ 0.5 V & 50mA ,
1.5 ms after closure
Across Contact
Contact to coil
Across Contact
Contact to coil
With nominal voltage
Measured w/ no coil suppression
0.5
0.1
0.2
4.0
0.2
4.0
0.7
0.1
ms
ms
pF
Across Contact
Contact to coil
For other load requirements, see the life test section on P. 112.
Environmental Data
Shock Resistance
Vibration Resistance
Ambient Temperature
Storage Temperature
Soldering Temperature
1/2 sine wave duration for 11 ms
50
20
-20
-25
70
85
260
-20
-35
50
20
70
95
260
g
g
o
From 10 - 2000 Hz
max. 10°C/ minute allowable
max. 10°C/ minute allowable
5 sec. dwell
C
C
C
o
o
* 4.25 kVDC / 3.0 kVRMS for Pin-outs 13 and 15.
www.meder.com
136