1~4 Output Medical Type
200W Medical series
Output Chart
OUTPUT CURRENT
RIPPLE & NOISE
(Max.)
VOLTAGE
TOLERANCE
(Note 3)
OUTPUT RATED
VOLTAGE CURRENT
LINE
LOAD
EFFICIENCY
(typ.)
PEAK LOAD
WITH 25CFM FAN
(Note 4)
MODEL
MINIMUM
LOAD
WITH FAN
(25CFM)
REGULATION REGULATION
CONVECTION
(max.)
(Note 2)
MPS-200-3.3 3.3V
40A
0A
0A
0A
0A
0A
0A
28A
28A
11.7A
9.4A
5.9A
3A
40A
48A
48A
20A
16A
10A
5A
80mVp-p
80mVp-p
100mVp-p
100mVp-p
150mVp-p
200mVp-p
2.0%
2.0%
2.0%
2.0%
1.0%
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
77%
81%
84%
85%
86%
87%
MPS-200-5
MPS-200-12
MPS-200-15
MPS-200-24
MPS-200-48
5V
40A
40A
12V
15V
24V
48V
16.7A
13.4A
8.4A
4.2A
16.7A
13.4A
8.4A
4.2A
MPD-200A
MPD-200B
5V
20A
8A
4A
15A
5.4A
15A
2.7A
20A
8A
24A
9.6A
24A
4.8A
80mVp-p
120mVp-p
80mVp-p
180mVp-p
2.0%
+8,-5%
2.0%
0.5%
1.0%
0.5%
1.0%
1.0%
4.0%
82%
83%
12V
5V
0.8A
4A
20A
4A
20A
4A
1.0%
24V
0.4A
6.5%
+4,-6%
MPT-200A
MPT-200B
MPT-200C
MPT-200D
5V
20A
7.5A
2A
4A
15A
5A
20A
7.5A
2A
24A
9A
80mVp-p
120mVp-p
80mVp-p
80mVp-p
120mVp-p
80mVp-p
80mVp-p
150mVp-p
80mVp-p
80mVp-p
180mVp-p
80mVp-p
2.0%
8.0%
5.0%
2.0%
8.0%
5.0%
2.0%
8.0%
5.0%
2.0%
8.0%
5.0%
0.5%
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
1.0%
0.5%
1.0%
5.0%
1.0%
1.0%
5.0%
1.0%
1.0%
5.0%
1.0%
1.0%
5.0%
1.0%
12V
-5V
5V
0.8A
0A
80%
80%
80%
81%
1A
2.4A
24A
7.2A
2.4A
24A
5.6A
2.4A
24A
3.6A
2.4A
20A
6A
4A
15A
4.4A
1A
20A
6A
12V
-12V
5V
0.6A
0A
2A
2A
20A
4.7A
2A
4A
15A
3.3A
1A
20A
4.7A
2A
15V
-15V
5V
0.5A
0A
20A
3A
4A
15A
2.2A
1A
20A
3A
24V
12V
0.3A
0A
2A
2A
MPQ-200B
MPQ-200C
MPQ-200D
MPQ-200F
5V
15A
7A
3A
12A
5.3A
1A
15A
7A
18A
8.4A
2.4A
2.4A
18A
6A
80mVp-p
120mVp-p
80mVp-p
80mVp-p
80mVp-p
150mVp-p
80mVp-p
80mVp-p
80mVp-p
180mVp-p
80mVp-p
80mVp-p
80mVp-p
180mVp-p
80mVp-p
80mVp-p
2.0%
8.0%
5.0%
5.0%
2.0%
6.0%
5.0%
5.0%
2.0%
8.0%
5.0%
5.0%
2.0%
8.0%
5.0%
5.0%
0.5%
1.0%
0.5%
0.5%
0.5%
1.0%
0.5%
0.5%
0.5%
1.0%
0.5%
0.5%
0.5%
1.0%
0.5%
0.5%
1.0%
5.0%
1.0%
1.0%
1.0%
5.0%
1.0%
1.0%
1.0%
5.0%
1.0%
1.0%
1.0%
5.0%
1.0%
1.0%
12V
-5V
-12V
5V
0.7A
0A
78%
78%
79%
81%
2A
2A
2A
0A
1A
2A
15A
5A
3A
12A
4A
15A
5A
15V
-5V
-15V
5V
0.5A
0A
2A
1A
2A
2.4A
2.4A
18A
3.6A
2.4A
2.4A
18A
3.3A
2.4A
2.4A
2A
0A
1A
2A
15A
3A
3A
12A
2.3A
1A
15A
3A
24V
12V
-12V
5V
0.3A
0A
2A
2A
2A
0A
1A
2A
15A
2.7A
2A
3A
12A
2.1A
1A
15A
2.7A
2A
24V
15V
-15V
0.3A
0A
2A
0A
1A
2A
Notes :
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 f & 47 f parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
6. Derating may be needed under low input voltages. Please check the derating curve for more details.
File Name:200W MEDICAL-SPEC 2008-03-25