1W SIP Package DC-DC Regulated Converter
SPRN01 & DPRN01 series
SPECIFICATION
VOLTAGE RANGE
SURGE VOLTAGE (100ms max.) 5Vin models : 9Vdc ; 12Vin models : 18Vdc ; 24Vin models : 30Vdc ; 48Vin models : 60Vdc
L: 4.75 ~ 5.5Vdc , M: 11.4 ~ 13.2Vdc , N: 22.8 ~ 26.4Vdc , O: 45.6 ~ 52.8Vdc
FILTER
Internal capacitor
INPUT
PROTECTION
Fuse recommended. 5Vin models: 500mA, 12Vin models: 250mA, 24Vin models: 100mA, 48Vin models: 60mA
INTERNAL POWER DISSIPATION 600mW
VOLTAGE ACCURACY
RATED POWER
3.0%
1W
RIPPLE & NOISE Note.2 75mVp-p
LINE REGULATION Note.3 1.0%
OUTPUT
LOAD REGULATION Note.4 1.0%
SWITCHING FREQUENCY (Typ.) 110KHz
PROTECTION
SHORT CIRCUIT
SPRN01: Current limit protection 60 sec. max., DPRN01: 1 sec. max.
Free-air convection
COOLING
-40 ~ +90℃ (Refer to "Derating Curve")
+110℃ max.
WORKING TEMP.
CASE TEMPERATURE
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
SOLDERING TEMPERATURE
VIBRATION
20% ~ 90% RH non-condensing
-55 ~ +125℃, 10 ~ 95% RH non-condensing
0.05% / ℃ (0 ~ 71℃)
ENVIRONMENT
1.5mm from case of 1 ~ 3sec./260℃ max.
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
EAC TP TC 004 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
ISOLATION CAPACITANCE (Typ.)
I/P-O/P:1.5KVDC
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
80pF
Parameter
Standard
Test Level / Note
Conducted
EN55032(CISPR32)
EN55032(CISPR32)
Standard
N/A
EMC EMISSION
SAFETY &
Radiated
Class B
EMC
( Note.5)
Parameter
Test Level / Note
ESD
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
Level 3, 8KV air, Level 2, 4KV contact
Level 2, 3V/m
Radiated Susceptibility
EFT/Burest
EMC IMMUNITY
Level 1, 0.5KV at power, Level 2, 0.5KV at signal
Level 2, 0.5KV Line-Line, Level 2, 1KV Line ground
Level 2, 3V(e.m.f.)
Level 1,1A/m
Surge
Conducted
Magnetic Field
1000Khrs MIL-HDBK-217F(25℃)
MTBF
19.6*7.1*10.14mm (0.77*0.28*0.40 inch)
DIMENSION (L*W*H)
CASE MATERIAL
PACKING
OTHERS
NOTE
Non-Conductive black plastic (UL 94V-0 rated)
2.5g
1.All parameters are specified at normal input(L:5Vdc, M:12Vdc, N:24Vdc, O:48Vdc), rated load, 25℃ 70% RH ambient.
2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1μf & 47μf capacitor.
3.Line regulation is measured from low line to high line at rated load.
4.Load regulation is measured from 10% to 100% rated load.
5.The final equipment must be re-confirm that it still meet EMC directives. For guidance on how to perform these EMC tests, please
refer to EMI testing of component power supplies.(as available on http://www.meanwell.com)
File Name:SPRN01,DPRN01-SPEC 2019-05-20