60W DIN Rail Type DC-DC Converter
DDR-60 series
SPECIFICATION
MODEL
DDR-60L-12 DDR-60L-15
DDR-60L-24
DDR-60G-5
DDR-60G-12 DDR-60G-15 DDR-60G-24
DDR-60L-5
DC VOLTAGE
5V
12V
15V
24V
12V
15V
5V
24V
RATED CURRENT
CURRENT RANGE
RATED POWER
10.8A
0 ~ 10.8A
54W
5A
4A
2.5A
5A
4A
12A
2.5A
0 ~ 5A
60W
0 ~ 4A
60W
0 ~ 2.5A
60W
0 ~ 5A
60W
0 ~ 4A
60W
0 ~ 12A
60W
0 ~ 2.5A
60W
OUTPUT
RIPPLE & NOISE (max.) Note.2 60mVp-p
75mVp-p
9 ~ 13.2V
2.0%
75mVp-p
13.5 ~ 16.5V
2.0%
100mVp-p
21.6 ~ 28V
2.0%
75mVp-p
9 ~ 13.2V
2.0%
75mVp-p
13.5 ~ 16.5V
2.0%
60mVp-p
4.5 ~ 5.5V
2.0%
100mVp-p
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3
LINE REGULATION
4.5 ~ 5.5V
2.0%
21.6 ~ 28V
2.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
SETUP, RISE TIME
1.5%
0.5%
0.5%
0.5%
1.5%
0.5%
0.5%
0.5%
120ms, 85ms at full load
L-type: 10ms@48Vdc input
6800 4700
HOLD UP TIME (Typ.)
G-type: 5ms@24Vdc input
EXTERNAL CAPACITANCE
LOAD (Max.)
6800
F
4700 F
μ
3300
F
2200 F
μ
F
μ
F
μ
3300 F
μ
2200 F
μ
μ
μ
VOLTAGE RANGE
EFFICIENCY (Typ.)
DC CURRENT (Typ.)
Note.4
9 ~ 36Vdc
87.5%
18 ~ 75Vdc
87.5%
91%
91%
91%
91%
92%
92%
INPUT
3A /24Vdc
20A /24Vdc
1.5A /48Vdc
20A /48Vdc
INRUSH CURRENT (Typ.)
105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
5.75 ~ 7V 13.8 ~ 16.2V
5.75 ~ 7V
13.8 ~ 16.2V
Protection type : Shut down o/p voltage, re-power on to recover
OVERLOAD
17.25 ~ 20.25V
28.8 ~ 34V
17.25 ~ 20.25V
28.8 ~ 34V
PROTECTION
OVER VOLTAGE
REVERSE POLARITY
UNDER VOLTAGE LOCKOUT
By internal MOSFET, no damage, recovers automatically after fault condition removed
24Vin (G-type):Power ON≥9V , OFF≤8.5V
48Vin (L-type):Power ON≥18V , OFF≤17V
-40 ~ +85℃ (Refer to "Derating Curve")
5 ~ 95% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
-40 ~ +85℃, 5 ~ 95% RH non-condensing
0.03%/℃ (0 ~60℃)
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
VIBRATION
2000 meters
OPERATING ALTITUDE
SAFETY STANDARDS
WITHSTAND VOLTAGE
IEC 62368-1 (LVD) approved, Design refer to UL508
I/P-O/P:4KVdc
ISOLATION RESISTANCE
I/P-O/P>100M Ohms / 500Vdc / 25℃/ 70% RH
Parameter
Standard
EN55032
Test Level / Note
Conducted
Class A
Radiated
EN55032
Class A for 1m I/O cable , Class B for 30cm I/O cable
-----
EMC EMISSION
SAFETY &
EMC
(Note 5)
Voltage Flicker
EN61000-3-3
EN55024 , EN61000-6-2(EN50082-2)
Parameter
Standard
Test Level / Note
ESD
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
Level 3, 8KV air ; Level 3, 6KV contact; criteria A
Level 3, 10V/m ; criteria A
Level 3, 2KV ; criteria A
Radiated
EFT / Burst
EMC IMMUNITY
Surge
Level 3, 1KV/Line-Line ; criteria A
Level 3, 10V ; criteria A
Conducted
Magnetic Field
Level 4, 30A/m ; criteria A
MTBF
611K hrs min. MIL-HDBK-217F (25℃)
52.5*90*54.5mm (W*H*D)
216g; 60pcs/14Kg/0.97CUFT
OTHERS
DIMENSION
PACKING
1. All parameters NOT specially mentioned are measured at normal input (G:24Vdc, L:48Vdc), rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the derating curve for more details.
NOTE
5.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC
directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
File Name:DDR-60-SPEC 2018-02-02