60W DIN Rail Type DC-DC Converter  
DDR-60 series  
SPECIFICATION  
MODEL  
DDR-60L-12 DDR-60L-15  
DDR-60L-24  
DDR-60G-5  
DDR-60G-12 DDR-60G-15 DDR-60G-24  
DDR-60L-5  
DC VOLTAGE  
5V  
12V  
15V  
24V  
12V  
15V  
5V  
24V  
RATED CURRENT  
CURRENT RANGE  
RATED POWER  
10.8A  
0 ~ 10.8A  
54W  
5A  
4A  
2.5A  
5A  
4A  
12A  
2.5A  
0 ~ 5A  
60W  
0 ~ 4A  
60W  
0 ~ 2.5A  
60W  
0 ~ 5A  
60W  
0 ~ 4A  
60W  
0 ~ 12A  
60W  
0 ~ 2.5A  
60W  
OUTPUT  
RIPPLE & NOISE (max.) Note.2 60mVp-p  
75mVp-p  
9 ~ 13.2V  
2.0%  
75mVp-p  
13.5 ~ 16.5V  
2.0%  
100mVp-p  
21.6 ~ 28V  
2.0%  
75mVp-p  
9 ~ 13.2V  
2.0%  
75mVp-p  
13.5 ~ 16.5V  
2.0%  
60mVp-p  
4.5 ~ 5.5V  
2.0%  
100mVp-p  
VOLTAGE ADJ. RANGE  
VOLTAGE TOLERANCE Note.3  
LINE REGULATION  
4.5 ~ 5.5V  
2.0%  
21.6 ~ 28V  
2.0%  
0.5%  
0.5%  
0.5%  
0.5%  
0.5%  
0.5%  
0.5%  
0.5%  
LOAD REGULATION  
SETUP, RISE TIME  
1.5%  
0.5%  
0.5%  
0.5%  
1.5%  
0.5%  
0.5%  
0.5%  
120ms, 85ms at full load  
L-type: 10ms@48Vdc input  
6800 4700  
HOLD UP TIME (Typ.)  
G-type: 5ms@24Vdc input  
EXTERNAL CAPACITANCE  
LOAD (Max.)  
6800  
F
4700 F  
μ
3300  
F
2200 F  
μ
F
μ
F
μ
3300 F  
μ
2200 F  
μ
μ
μ
VOLTAGE RANGE  
EFFICIENCY (Typ.)  
DC CURRENT (Typ.)  
Note.4  
9 ~ 36Vdc  
87.5%  
18 ~ 75Vdc  
87.5%  
91%  
91%  
91%  
91%  
92%  
92%  
INPUT  
3A /24Vdc  
20A /24Vdc  
1.5A /48Vdc  
20A /48Vdc  
INRUSH CURRENT (Typ.)  
105 ~ 135% rated output power  
Protection type : Constant current limiting, recovers automatically after fault condition is removed  
5.75 ~ 7V 13.8 ~ 16.2V  
5.75 ~ 7V  
13.8 ~ 16.2V  
Protection type : Shut down o/p voltage, re-power on to recover  
OVERLOAD  
17.25 ~ 20.25V  
28.8 ~ 34V  
17.25 ~ 20.25V  
28.8 ~ 34V  
PROTECTION  
OVER VOLTAGE  
REVERSE POLARITY  
UNDER VOLTAGE LOCKOUT  
By internal MOSFET, no damage, recovers automatically after fault condition removed  
24Vin (G-type):Power ON9V , OFF8.5V  
48Vin (L-type):Power ON18V , OFF17V  
-40 ~ +85(Refer to "Derating Curve")  
5 ~ 95% RH non-condensing  
WORKING TEMP.  
WORKING HUMIDITY  
-40 ~ +85, 5 ~ 95% RH non-condensing  
0.03%/(0 ~60)  
ENVIRONMENT STORAGE TEMP., HUMIDITY  
TEMP. COEFFICIENT  
Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6  
VIBRATION  
2000 meters  
OPERATING ALTITUDE  
SAFETY STANDARDS  
WITHSTAND VOLTAGE  
IEC 62368-1 (LVD) approved, Design refer to UL508  
I/P-O/P:4KVdc  
ISOLATION RESISTANCE  
I/P-O/P>100M Ohms / 500Vdc / 25/ 70% RH  
Parameter  
Standard  
EN55032  
Test Level / Note  
Conducted  
Class A  
Radiated  
EN55032  
Class A for 1m I/O cable , Class B for 30cm I/O cable  
-----  
EMC EMISSION  
SAFETY &  
EMC  
(Note 5)  
Voltage Flicker  
EN61000-3-3  
EN55024 , EN61000-6-2(EN50082-2)  
Parameter  
Standard  
Test Level / Note  
ESD  
EN61000-4-2  
EN61000-4-3  
EN61000-4-4  
EN61000-4-5  
EN61000-4-6  
EN61000-4-8  
Level 3, 8KV air ; Level 3, 6KV contact; criteria A  
Level 3, 10V/m ; criteria A  
Level 3, 2KV ; criteria A  
Radiated  
EFT / Burst  
EMC IMMUNITY  
Surge  
Level 3, 1KV/Line-Line ; criteria A  
Level 3, 10V ; criteria A  
Conducted  
Magnetic Field  
Level 4, 30A/m ; criteria A  
MTBF  
611K hrs min. MIL-HDBK-217F (25)  
52.5*90*54.5mm (W*H*D)  
216g; 60pcs/14Kg/0.97CUFT  
OTHERS  
DIMENSION  
PACKING  
1. All parameters NOT specially mentioned are measured at normal input (G:24Vdc, L:48Vdc), rated load and 25of ambient temperature.  
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor.  
3. Tolerance : includes set up tolerance, line regulation and load regulation.  
4. Derating may be needed under low input voltage. Please check the derating curve for more details.  
NOTE  
5.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC  
directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”  
(as available on http://www.meanwell.com)  
6. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft).  
File Name:DDR-60-SPEC 2018-02-02  
 复制成功!