60W Single Output LED Power Supply
Features :
CLG-60
series
Universal AC input / Full range
(up to 295VAC)
Built-in active PFC function
High efficiency up to 89%
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
IP67 design for indoor or outdoor installations
Class 2 power unit
Pass LPS
100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications
(Note.2)
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet locations
3 years warranty
F
110
M
M
SELV
LPS
CLG-60-15
15V
10.5 ~ 15V
4A
0 ~ 4A
60W
2.4Vp-p
( for 48V only)
( except for 48V )
IP67
CLG-60-27
27V
18.9 ~ 27V
2.3A
0 ~ 2.3A
62.1W
2.7Vp-p
25 ~ 30V
CLG-60-36
36V
25.2 ~ 36V
1.7A
0 ~ 1.7A
61.2W
3.6Vp-p
32.5 ~ 39V
(option)
for 20~27V
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
CLG-60-12
12V
5A
0 ~ 5A
60W
11.5 ~ 13V
CONSTANT CURRENT REGION
Note.5
8.4 ~ 12V
CLG-60-20
20V
14 ~ 20V
3A
0 ~ 3A
60W
1.8Vp-p
19.5 ~ 22V
CLG-60-24
24V
16.8 ~ 24V
2.5A
0 ~ 2.5A
60W
2.7Vp-p
24 ~ 26V
CLG-60-48
48V
33.6 ~ 48V
1.3A
0 ~ 1.3A
62.4W
4.6Vp-p
43.6 ~ 51.8V
RIPPLE & NOISE (max.)
Note.2
2Vp-p
VOLTAGE ADJ. RANGE
CURRENT ADJ. RANGE
VOLTAGE TOLERANCE
Note.3
LINE REGULATION
LOAD REGULATION
SETUP TIME
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
INPUT
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT(max.)
LEAKAGE CURRENT
OVER CURRENT
SHORT CIRCUIT
PROTECTION
OVER VOLTAGE
14.5 ~ 16.2V
Fixed can be modified between the range above
Fixed. Can be modified between 3% ~ -25% rated output current
10%
3.0%
5.0%
3000ms / 230VAC 5000ms / 115VAC at full load
Note.4
90 ~ 295VAC
127 ~ 417VDC
47 ~ 63Hz
PF>0.94/115VAC, PF>0.9/230VAC, PF>0.9/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
85%
0.8A/115VAC
40A/230VAC
<0.75mA / 240VAC
95 ~ 110%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed
13.8 ~ 16V
17.5 ~ 21V
23 ~ 26V
28 ~ 32V
Protection type : Shut down o/p voltage, re-power on to recover
12V: 90
10
(TSW1) detect on heatsink of power transistor
10
(TSW1) detect on heatsink of power transistor
15V ~ 48V: 85
-30 ~ +70
31 ~ 35V
41 ~ 46V
54 ~ 60V
86%
0.4A/230VAC
87.5%
0.3A/277VAC
87%
88%
89%
89%
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
MTBF
OTHERS
DIMENSION
PACKING
NOTE
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
(Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
0.03%/
(0 ~ 50 )
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL879, UL8750, UL1310, TUV EN61347-1, EN61347-2-13 independent, CAN/CSA C22.2 No. 223-M91(except for 48V),
CSA C22.2 No. 250.0-08(except for 48V), CSA C22.2 No. 207-M89(except for 48V), IP67, J61347-1, J61347-2-13(option) approved
I/P-O/P:3.75KVAC
I/P-FG:1.88KVAC
O/P-FG:0.5KVAC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C ( 75% load) ; EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61547, light industry level (surge 4KV), criteria A
495.7Khrs min. MIL-HDBK-217F (25 )
195.6*61.5*38.8mm (L*W*H)
0.86Kg; 16pcs/14.8Kg/0.54CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. Constant current operation region is within 70% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
6. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
7. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
File Name:CLG-60-SPEC 2012-03-01