100W Single Output LED Power Supply
�½
Features :
CEN-100
series
Universal AC input / Full range (up to 295VAC)
Protections: Short circuit / Over current / Over voltage / Over temperature
Output voltage and constant current level adjustable
Built-in active PFC function
IP66 design for indoor or outdoor installations
Cooling by free air convection
100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet locations
3 years warranty
F
110
SELV
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
CEN-100-20
20V
4.8A
0 ~ 4.8A
96W
CONSTANT CURRENT OPERATION VOLTAGE
Note.5
13 ~ 20V
CEN-100-24
24V
15.6 ~ 24V
4A
0 ~ 4A
96W
2.7Vp-p
22 ~ 27V
2.6 ~ 4A
CEN-100-30
30V
19.5 ~ 30V
3.2A
0 ~ 3.2A
96W
3Vp-p
27 ~ 33V
2.08 ~ 3.2A
IP66
CEN-100-36
36V
23.4 ~ 36V
2.65A
0 ~ 2.65A
95.4W
3.6Vp-p
33 ~ 40V
1.72 ~ 2.65A
CEN-100-42
42V
27.3 ~ 42V
2.28A
0 ~ 2.28A
95.76W
4Vp-p
37 ~ 46V
1.48 ~ 2.28A
CEN-100-48
48V
31.2 ~ 48V
2A
0 ~ 2A
96W
4.6Vp-p
43 ~ 53V
1.3 ~ 2A
CEN-100-54
54V
35.1 ~ 54V
1.77A
0 ~ 1.77A
95.58W
5Vp-p
49 ~ 58V
1.15 ~ 1.77A
RIPPLE & NOISE (max.)
Note.2
2.0Vp-p
VOLTAGE ADJ. RANGE
(SVR1)
17 ~ 22V
CURRENT ADJ. RANGE
(SVR2)
3.12 ~ 4.8A
VOLTAGE TOLERANCE
Note.3
LINE REGULATION
LOAD REGULATION
SETUP TIME
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
INPUT
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER CURRENT
SHORT CIRCUIT
PROTECTION
OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY &
EMC
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
MTBF
OTHERS
DIMENSION
PACKING
NOTE
10%
3.0%
5.0%
3000ms / 230VAC 5000ms / 115VAC at full load
Note.4
90 ~ 295VAC
127 ~ 417VDC
47 ~ 63Hz
PF>0.97/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
88%
1.4A/115VAC
60A/230VAC
89%
0.7A/230VAC
90%
90%
90%
91%
91%
<0.75mA / 240VAC
95 ~ 110%
Protection type :
Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed
22.8 ~ 26V
28 ~ 32V
34 ~ 38V
41 ~ 46V
Protection type : Shut down o/p voltage, re-power on to recover
100
10
(RTH1)
(Refer to "Derating Curve")
, 10 ~ 95% RH
(0 ~ 50
)
Protection type : Shut down o/p voltage, re-power on to recover
-30 ~ +70
-40 ~ +80
0.03%/
20 ~ 95% RH non-condensing
47 ~ 52V
54 ~ 60V
59 ~ 65V
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL8750, TUV EN61347-1, EN61347-2-13, J61347-1, J61347-2-13, IP66 approved
I/P-O/P:3.75KVAC
I/P-FG:1.88KVAC
O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG: >100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN61000-3-2 Class C ( 65% load) ; EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61547, light industry level (surge 4KV), criteria A
519.5Khrs min. MIL-HDBK-217F (25
193*62.5*40.5mm (L*W*H)
0.6Kg; 24pcs/15.4Kg/1.11CUFT
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. Constant current operation region is within 65% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
6. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
7. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
File Name:CEN-100-SPEC 2011-07-28