150W Single Output with PFC Function
Features :
ASP-150
series
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
High power density 8.4w/in
3
100% full load burn-in test
No load power consumption<1W@240VAC
ZCS/ZVS technology to reduce power dissipation
3 years warranty
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
ASP-150-12
12V
11A
0 ~ 11A
132W
11 ~ 13.2V
ASP-150-15
15V
9.5A
0 ~ 9.5A
142.5W
180mVp-p
14 ~ 17V
ASP-150-20
20V
7.5A
0 ~ 7.5A
150W
200mVp-p
17 ~ 22V
ASP-150-24
24V
6.3A
0 ~ 6.3A
151.2W
240mVp-p
22 ~ 27V
1.0%
0.5%
0.5%
ASP-150-48
48V
3.2A
0 ~ 3.2A
153.6W
240mVp-p
45.6 ~ 52.8V
1.0%
0.5%
0.5%
RIPPLE & NOISE (max.)
Note.2
150mVp-p
OUTPUT
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
Note.3
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
INPUT
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY &
EMC
(Note 4)
Fixed. Can be modified between the range above by factory
2.0%
2.0%
1.0%
0.5%
1.0%
3000ms, 80ms at full load
50ms/230VAC
90 ~ 264VAC
47 ~ 63Hz
PF 0.95/230VAC
88%
2A/115VAC
PF 0.98/115VAC at full load
88%
1A/230VAC
90%
16ms/115VAC at full load
127 ~ 370VDC
0.5%
1.0%
0.5%
0.5%
90%
89%
COLD START 80A/230VAC
<2mA / 240VAC
105 ~ 135%
rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
17.5 ~ 20.25V
22.5 ~ 28V
27.5 ~ 32.4V
13.7 ~ 16.2V
Protection type : Shut down o/p voltage, re-power on to recover
90
10
(RTH2) detect on heatsink of power transistor
Protection type : Shut down o/p voltage, re-power on to recover
-20 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85
, 10 ~ 95% RH
0.05%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, CB(IEC60950-1) approved
I/P-O/P:4.25KVDC
I/P-FG:1.5KVAC
O/P-FG:0.5KVAC
/ 70% RH
53.3 ~ 64.8V
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25
EMI CONDUCTION & RADIATION
Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
MTBF
149.3Khrs min. MIL-HDBK-217F (25
169*60.7*28.5mm (L*W*H)
0.32Kg; 48pcs/15.8Kg/0.79CUFT
)
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, light industry level, criteria A
OTHERS
NOTE
DIMENSION
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. Heat Sink HS1,HS3 & HS2,HS3 can not be shorted.
File Name:ASP-150-SPEC 2010-10-18