欢迎访问ic37.com |
会员登录 免费注册
发布采购

600S-N015 参数 Datasheet PDF下载

600S-N015图片预览
型号: 600S-N015
PDF下载: 下载PDF文件 查看货源
内容描述: 600W单路输出带并联功能 [600W Single Output With Parallel Function]
分类和应用:
文件页数/大小: 3 页 / 341 K
品牌: MEANWELL [ MEAN WELL ENTERPRISES CO., LTD. ]
 浏览型号600S-N015的Datasheet PDF文件第2页浏览型号600S-N015的Datasheet PDF文件第3页  
600W Single Output With Parallel Function
Features :
SCN-600
series
AC input range selected by switch
Protections: Short circuit / Overload / Over voltage / Over temp.
High reliability/ Low ripple noise
Built-in remote sense function
Built-in remote ON-OFF control
Built-in parallel operation function
Can adjust from 20~100% output voltage by external control 1-5V
Forced air cooling by built-in DC fan
Case coating with paint
2 years warranty
SPECIFICATION
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
VOLTAGE RANGE
FREQUENCY RANGE
INPUT
EFFICIENCY (Typ.)
AC CURRENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT
OVERLOAD
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY &
EMC
(Note. 4)
SCN-600-05
600S-N005
5V
100A
0 ~ 100A
500W
SCN-600-12
600S-N012
12V
50A
0 ~ 50A
600W
120mVp-p
SCN-600-15
600S-N015
15V
40A
0 ~ 40A
600W
150mVp-p
SCN-600-18
600S-N018
18V
33A
0 ~ 33A
594W
180mVp-p
SCN-600-24
600S-N024
24V
25A
0 ~ 25A
600W
240mVp-p
SCN-600-48
600S-N048
48V
12A
0 ~ 12A
576W
480mVp-p
1.0%
0.5%
0.5%
RIPPLE & NOISE (max.)
Note.2
100mVp-p
5.0% typical adjustment by potentiometer
1.0%
VOLTAGE TOLERANCE
Note.3
1.5%
0.5%
1.0%
0.5%
0.5%
20~100% adjustment by 1~5VDC external control
1.0%
1.0%
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
SETUP, RISE, HOLD UP TIME
800ms, 50ms, 16ms at full load
90 ~ 130VAC / 180 ~ 260VAC selected by switch, 260 ~ 370VDC
47 ~ 63Hz
77%
11A / 115VAC
60A / 230VAC
3.5mA / 240VAC
101 ~ 115%
110 ~ 135% rated output power
Protection type : Current limiting, delay shut down o/p voltage, re-power on to recover
110 ~ 135% follow to output set up point
Protection type : Shut down o/p voltage, re-power on to recover
>100 / measure by heat sink, near transformer
Protection type : Shut down o/p voltage, re-power on to recover
-10 ~ +65 (Refer to output load derating curve)
20% ~ 90% RH non-condensing
-20 ~ +85
, 10 ~ 95% RH
0.04% / (0 ~ 50 )
10 ~ 200Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, CSA22.2, IEC60950 approved
I/P-O/P, I/P-FG:1500VAC
I/P-O/P, I/P-FG, 100M Ohms / 500VDC / 25
/ 70% RH
80%
7.0A / 230VAC
81%
82%
85%
87%
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
Compliance to FCC part 15 class A
----
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
SPECIAL FUNCTION
----
120Khrs min. MIL-HDBK-217F (25 )
291*132*68mm (L*W*H)
2.6kg; 8pcs/ 24kg/ CARTON
DC voltage adj., Remote sensing, remote control, parallel operation (refer to terminal instruction manual)
OTHERS
NOTE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.Tolerence: includes set up tolerance, line regulation, load regulation.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:SCN-600-SPEC 2008-05-06