MX29LV160BT/BB
in the improper sequence will reset the device to the
read mode. Table 5 defines the valid register command
sequences. Note that the Erase Suspend (B0H) and
Erase Resume (30H) commands are valid only while the
Sector Erase operation is in progress.
COMMAND DEFINITIONS
Device operations are selected by writing specific ad-
dress and data sequences into the command register.
Writing incorrect address and data values or writing them
TABLE 5. MX29LV160BT/BB COMMAND DEFINITIONS
First Bus
Bus Cycle
Second Bus Third Bus
Fourth Bus
Cycle
Fifth Bus
Cycle
Sixth Bus
Cycle
Command
Cycle
Cycle
Cycle Addr Data Addr
Data Addr
Data Addr Data Addr
Data Addr Data
Reset
1
1
4
4
4
XXXH F0H
RA RD
Read
Read Silicon ID Word
Byte
555H AAH 2AAH 55H 555H 90H ADI
AAAH AAH 555H 55H AAAH 90H ADI
DDI
DDI
Sector Protect
Verify
Word
555H AAH 2AAH 55H 555H 90H (SA) XX00H
x02H XX01H
Byte
4
AAAH AAH 555H 55H AAAH 90H (SA) 00H
x04H 01H
Program
Word
Byte
Word
Byte
Word
Byte
4
4
6
6
6
6
1
1
1
555H AAH 2AAH 55H 555H A0H PA
AAAH AAH 555H 55H AAAH A0H PA
PD
PD
Chip Erase
Sector Erase
555H AAH 2AAH 55H 555H 80H 555H AAH 2AAH 55H
555H 10H
AAAH 10H
AAAH AAH 555H 55H AAAH 80H AAAH AAH 555H 55H
555H AAH 2AAH 55H 555H 80H 555H AAH 2AAH 55H
SA
SA
30H
30H
AAAH AAH 555H 55H AAAH 80H AAAH AAH 555H 55H
Sector Erase Suspend
Sector Erase Resume
XXXH B0H
XXXH 30H
55H 98
AAH
CFI Query
Word
Byte
Note:
1. ADI = Address of Device identifier; A1=0, A0 = 0 for manufacturer code,A1=0, A0 = 1 for device code. A2-A19=do not care.
(Refer to table 3)
DDI = Data of Device identifier : C2H for manufacture code, C4H/49H (x8) and 22C4H/2249H (x16) for device code.
X = X can be VIL or VIH
RA=Address of memory location to be read. RD=Data to be read at location RA.
2.PA = Address of memory location to be programmed. PD = Data to be programmed at location PA.
SA = Address of the sector to be erased.
3.The system should generate the following address patterns: 555H or 2AAH to Address A10~A0 in word mode/AAAH or
555H to Address A10~A-1 in byte mode.
Address bit A11~A19=X=Don't care for all address commands except for Program Address (PA) and Sector
Address (SA). Write Sequence may be initiated with A11~A19 in either state.
4. For Sector Protect Verify operation: If read out data is 01H, it means the sector has been protected. If read out data is 00H,
it means the sector is still not being protected.
5. Any number of CFI data read cycles are permitted.
P/N:PM1041
REV. 1.2, JUL. 01, 2004
10