MX29LV64xM H/L
AC CHARACTERISTICS
Read-Only Operations
Parameter
TA=-40°C to 85°C, VCC=2.7V~3.6V
Speed Options
Std.
tRC
Description
Test Setup
90
90
90
90
25
35
16
16
0
Unit
ns
ns
ns
ns
ns
ns
ns
ns
Read CycleTime (Note 1)
Address to Output Delay
Min
CE#, OE#=VIL Max
tACC
tCE
Chip Enable to Output Delay
Page Access Time
OE#=VIL
Max
Max
Max
Max
Max
Min
tPACC
tOE
tDF
Output Enable to Output Delay
Chip Enable to Output High Z (Note 1)
Output Enable to Output High Z (Note 1)
Output HoldTime From Address, CE#
or OE#, whichever Occurs First
Read
tDF
tOH
Min
Min
35
10
ns
ns
tOEH
Output Enable HoldTime Toggle and
(Note 1)
Data# Polling
Notes:
1. Not 100% tested.
2. See SWITCHING TEST CIRCUITS and TEST SPECIFICATIONS TABLE for test specifications.
P/N:PM1093
REV. 1.1, AUG. 11, 2005
34