MX23J12840  
Sequential Read  
In read modes (1), (2), and (3), when a command (00H, 01H, 50H) is input and an address specified, if it is in the  
block that includes the address that was specified first, the address is automatically incremented and the read  
operation is continuously performed until the last address in the same block, by inputting the RE# clock. At this time,  
a Busy period (tR) occurs after the last address is accessed in a page.  
Note  
Command  
input  
Command  
input  
Address  
input  
Page M  
data output  
Page M+1  
data output  
Output of in last page  
in block  
Address  
input  
Data output  
00H  
01H  
50H  
00H  
01H  
50H  
Note  
tR  
tR  
tR  
tR  
tCRY  
tR  
RB  
Busy  
Busy  
Busy  
Busy  
Busy  
Busy  
In same block  
(Maximum of 32 pages)  
Note :To perform read again after reading the 527th byte of data of the last page of block, stop the read operation once, and  
then restart the read operation by inputting again the read command and an address.  
Relationship Between Command and Start Address (SA) during Sequential Read  
(A)  
(B)  
(C)  
(A)  
(B)  
(C)  
(A)  
(B)  
(C)  
0
256  
512 527  
256  
512 527  
256  
512 527  
SA  
SA  
SA  
1block  
=32 pages  
Note  
Sequential read mode (1)  
(When "00H" command is input)  
Sequential read mode (2)  
(When "01H" command is input)  
Sequential read mode (3)  
(When "50H" command is input)  
Note : When the "50H" command is set, only the (C) area (redundancy data part) is continuously read.  
When the "00H" command is set, the start address (SA) is set to area (A).  
When the "01H" command is set, the start address (SA) is set to area (B).  
When the "50H" command is set, the start address (SA) is set to area (C).  