80386DX
32-Bit Microprocessor
TABLE 6. 80386DX AC ELECTRICAL CHARACTERISTICS
(VCC = +5V ±10%; V = V ; T = -55°C TO +125°C, UNLESS OTHERWISE SPECIFIED)
PP
SS
A
PARAMETER
RESET Hold Time
SYMBOL
CONDITION
MIN
MAX
UNIT
t26
ns
-16
-20
-25
4
4
3
--
--
--
NMI, INTR Setup Time3
t27
t28
t29
t30
ns
ns
ns
ns
-16
-20
-25
16
16
6
--
--
--
NMI, INTR Hold Time3
-16
-20
-25
16
16
6
--
--
--
REREQ, ERROR, BUSY Setup Time3
-16
-20
-25
16
14
6
--
--
--
REREQ, ERROR, BUSY Hold Time3
-16
-20
-25
5
5
5
--
--
--
1. Guaranteed by design.
2. Float condition occurs when maximum when output current becomes less than ILO in magnitude.
3. These inputs are allowed to be asynchronous to CLK2. The setup and hold specifications are given for testing purposes, to
assure recognition within a specific CLK2 period.
1000557
12.17.01 Rev1
All data sheets are subject to change without notice
7
©2001 Maxwell Technologies
All rights reserved.