TABLE IIA. Electrical test requirements. 1/ 2/ 3/ 4/ 5/ 6/ 7/
Line
no.
Test
requirements
Subgroups
(per method
5005, table I)
Subgroups
(per MIL-PRF-38535,
table III)
Device
class M
Device
class Q
Device
class V
1
2
Interim electrical
parameters (see 4.2)
1,7,9 or
2,8A,10
1,7,9 or
1,2,8A,10
Static burn-in I
method 1015
Not
required
Not
required
Required
3
4
Same as line 1
1*,7*
Dynamic burn-in
(method 1015)
Required
Required
Required
5
6
Same as line 1
1*,7*
Final electrical
parameters
1*,2,3,7*,
1*,2,3,7*,
1*,2,3,7*,
8A,8B,9,10,11 8A,8B,9,10,11 8A,8B,9,10,11
7
8
Group A test
requirements
1,2,3,4**,7,8A, 1,2,3,4**,7, 1,2,3,4**,7,
8B,9,10,11
2,3,7,8A,8B
8A,8B,9,10,11 8A,8B,9,10,11
1,2,3,7,8A,8B, 1,2,3,7,8A,8B,
Group C end-point
electrical
9,10, 11
9,10,11
parameters
9
Group D end-point
electrical parameters
2,3,7,8A,8B
1,7,9
2,3,7
8A,8B
2,3,7,
8A,8B
10
Group E end-point
1,7,9
1,7,9
electrical parameters
1/ Blank spaces indicate test are not applicable.
2/ Any or all subgroups may be combined when using high-speed testers.
3/ Subgroups 7 and 8 functional tests shall verify the truth table.
4/ * Indicates PDA applies to subgroups 1 and 7.
5/ ** See 4.4.1c.
6/
Indicates delta limit (see table IIB) shall be required where specified, and the delta values
shall be computed with reference to the previous interim electrical parameters (see line 1).
7/ See 4.4.1e.
TABLE IIB. Delta limits at +25 C.
Test 1/
All device types
I
I
I
standby
± 10% of specified
value in table I
CC3
, I
± 10% of specified
value in table I
IH IL
, I
OHZ OLZ
± 10% of specified
value in table I
1/ The above parameters shall be recorded
before and after the required burn-in and
life tests to determine the delta
.
SIZE
STANDARD
5962-38267
A
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
REVISION LEVEL
G
SHEET
34
DSCC FORM 2234
APR 97