Power-Supply Monitor with Reset
MAX700/MAX701/MAX702
ABSOLUTE MAXIMUM RATINGS
V
CC
......................................................................-0.3V to +15.5V
Voltage (with respect to GND) at RESET,
RESET,
HYST, CTL, SENSE ............................................-0.3V to V
CC
Operating Temperature Range
C Suffix .............................................................0°C to +70°C
E Suffix...........................................................-40°C to +85°C
Rate of Rise, V
CC
............................................................100V/µs
Power Dissipation, Any Package .....................................380mW
Storage Temperature Range .............................-55°C to +150°C
Lead Temperature (soldering, 10s)..................................+300°C
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
ELECTRICAL CHARACTERISTICS
(V
CC
= +5V, CTL = GND on MAX700, T
A
= +25°C, unless otherwise noted.)
PARAMETER
V
CC
Monitor Voltage Range
(MAX700 Only)
Min V
CC
for Valid Reset Output,
Declining Supply
Supply Current
Reset Threshold
Internal Hysteresis
Reset Output Pulse Width
RESET Fall Time
V
CC
Pulse Duration Guaranteeing
MR Input Threshold
MR Pullup Current
MAX700
RESET Output Low
I
SINK
= 3.2mA, V
CC
= 5V
I
SINK
= 1.6mA, V
CC
= 3V
I
SOURCE
= 3.2mA, V
CC
= 4.25V
RESET Output High
I
SOURCE
= 1.6mA, V
CC
= 3V
I
SOURCE
= 0.5mA, V
CC
= 1.5V
I
SINK
= 16mA, V
CC
= 4.25V
RESET
Output Low
I
SINK
= 1.6mA, V
CC
= 3V
I
SINK
= 0.4mA, V
CC
= 1.5V
I
SOURCE
= 3.2mA, V
CC
= 5V
RESET
Output High
I
SOURCE
= 1.6mA, V
CC
= 3V
V
CC
-
0.4
V
V
CC
-
0.4
V
CC
-
0.4
V
CC
-
0.4
V
CC
-
0.4
0.4
0.4
0.4
V
V
0.4
0.4
V
MAX700/MAX701 only, C
LOAD
= 100pF
5V to 4V V
CC
pulse
No reset
Reset
100
T
A
= T
MIN
to T
MAX
HYST not connected
200
Power-up
Power-down
4.50
4.50
CONDITIONS
T
A
= T
MIN
to T
MAX
, CTL = V
CC
T
A
= T
MIN
to T
MAX
,
RESET
≤
0.4V when sinking 1mA
MIN
3
1.5
1
100
4.65
4.62
30
350
200
10
10
0.7
-5
-30
1
500
200
4.75
4.75
TYP
MAX
15
UNITS
V
V
µA
V
mV
ms
ns
µs
V
µA