 浏览型号MAX6657MSA+T的Datasheet PDF文件第8页浏览型号MAX6657MSA+T的Datasheet PDF文件第9页浏览型号MAX6657MSA+T的Datasheet PDF文件第10页浏览型号MAX6657MSA+T的Datasheet PDF文件第11页浏览型号MAX6657MSA+T的Datasheet PDF文件第12页浏览型号MAX6657MSA+T的Datasheet PDF文件第14页浏览型号MAX6657MSA+T的Datasheet PDF文件第15页浏览型号MAX6657MSA+T的Datasheet PDF文件第16页  
±±1°C ꢀMꢁusꢂ°oꢃpatiꢄle ꢅeꢃote/ꢆocal eꢃperature  
ꢀensors with Overteꢃperature Alarꢃs  
78/MAX659  
ALERT output follows the status flag bit. Both are  
cleared when successfully read, but if the condition still  
exists, they reassert at the end of the next conversion.  
ꢀtatus ꢁyte Functions  
The status byte (Table 6) indicates which (if any) tem-  
perature thresholds have been exceeded. This byte also  
indicates whether the ADC is converting and if there is  
an open-circuit fault detected with the external sense  
junction. After POR, the normal state of the MSB is 1 and  
all the other flag bits are 0, assuming no alert or  
overtemperature conditions are present. Bits 2 through  
6 of the Status register are cleared by any successful  
read of the Status register, unless the fault persists. The  
The bits indicating OVERT1 (bits 0 and 1) are cleared  
only when the condition no longer exists. Reading the  
status byte does not clear the OVERT1 outputs or fault  
bits. One way to eliminate the fault condition is for the  
measured temperature to drop below the temperature  
threshold minus the hysteresis value. Another way to  
eliminate the fault condition is by writing new values for  
the OVERT1 threshold or hysteresis so that a fault con-  
dition is no longer present. Note that the status byte  
does not provide status of OVERT2.  
Table 5. Configuration-Byte Bit  
Assignments  
The MAX6657/MAX6658/MAX6659 incorporate collision  
avoidance so that completely asynchronous operation  
is allowed between SMBus operations and temperature  
conversions.  
POR  
STATE  
BIT  
NAME  
FUNCTION  
7
MASK1  
0
Masks ALERT interrupts if a 1.  
(MSB)  
When autoconverting, if the T  
and T  
limits are  
LOW  
HIGH  
close together, it’s possible for both high-temp and low-  
temp status bits to be set, depending on the amount of  
time between status read operations. In these circum-  
stances, it is best not to rely on the status bits to indi-  
cate reversals in long-term temperature changes.  
Instead, use a current temperature reading to establish  
the trend direction.  
Standby mode control bit; if a  
1, standby mode is initiated.  
6
RUN/STOP  
0
Set to 1 when the remote  
sensor is a substrate or  
common collector PNP. Set to 0  
when the remote sensor is a  
diode-connected discrete  
transistor.  
5
SPNP  
RFU  
1
0
°onversion ꢅate ꢁyte  
The Conversion Rate register (Table 7) programs the  
time interval between conversions in free-running  
autonomous mode (RUN/STOP = 0). This variable rate  
4 to 0  
Reserved  
Table 6. Status Register Bit Assignments  
BIT  
NAME  
POR STATE  
FUNCTION  
7 (MSB)  
BUSY  
1
A/D is busy converting when high.  
Internal high-temperature alarm has tripped when high; cleared by POR or readout of  
the Status register if the fault condition no longer exists.  
6
5
4
3
2
1
0
LHIGH  
LLOW  
RHIGH  
RLOW  
OPEN  
EOT1  
0
0
0
0
0
0
0
Internal low-temperature alarm has tripped when high; cleared by POR or readout of  
the Status register if the fault condition no longer exists.  
External high-temperature alarm has tripped when high; cleared by POR or readout of  
the Status register if the fault condition no longer exists.  
External low-temperature alarm has tripped when high; cleared by POR or readout of  
the Status register if the fault condition no longer exists.  
A high indicates an external diode open; cleared by POR or readout of the Status  
register if the fault condition no longer exists.  
A high indicates the external junction temperature exceeds the external OVERT1  
threshold.  
A high indicates the internal junction temperature exceeds the internal OVERT1  
threshold.  
IOT1  
______________________________________________________________________________________ 13