±1°C, SMBus-Compatible Remote/Local Temperature
Sensors with Overtemperature Alarms
MAX6657/MAX6658/MAX6659
ABSOLUTE MAXIMUM RATINGS
All Voltages Referenced to GND
V
CC
..........................................................................-0.3V to +6V
DXP ............................................................-0.3V to (V
CC
+ 0.3V)
DXN ......................................................................-0.3V to +0.8V
SMBCLK, SMBDATA,
ALERT, OVERT1,
OVERT2
..............................................................-0.3V to +6V
SMBDATA,
ALERT, OVERT1, OVERT2
Current ..........................................................-1mA to +50mA
DXN Current ......................................................................±1mA
Continuous Power Dissipation (T
A
= +70°C)
8-Pin SO (derate 5.9mW/°C above +70°C) .................471mW
16-Pin QSOP (derate 8.3mW/°C above +70°C) ..........664mW
Junction Temperature .....................................................+150°C
Storage Temperature Range ............................-65°C to +150°C
Lead Temperature (soldering, 10s) ................................+300°C
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
ELECTRICAL CHARACTERISTICS
(Circuit of Typical Operating Circuit, V
CC
= +3.0V to +5.5V, T
A
= 0°C to +125°C, unless otherwise specified. Typical values are at
V
CC
= +3.3V and T
A
= +25°C.)
PARAMETER
Temperature Resolution,
Legacy Mode
Temperature Resolution,
Extended Mode
T
RJ
= +60°C to +100°C, V
CC
= +3.3V
(Note 1)
T
RJ
= 0°C to +100°C, V
CC
= +3.3V (Note 1)
T
RJ
= 0°C to +125°C, V
CC
= +3.3V (Note 1)
Local Temperature Error
(MAX6657)
T
A
= +60°C to +100°C, V
CC
= +3.3V
T
A
= 0°C to +100°C, V
CC
= +3.3V
T
A
= 0°C to +125°C, V
CC
= +3.3V
Remote Temperature Error
(MAX6658/MAX6659)
T
RJ
= +60°C to +100°C, V
CC
= +3.3V
(Note 1)
T
RJ
= 0°C to +100°C, V
CC
= +3.3V (Note 1)
T
RJ
= -55°C to +125°C, V
CC
= +3.3V (Note 1)
Local Temperature Error
(MAX6658/MAX6659)
Line Regulation
Supply Voltage Range
Undervoltage Lockout Threshold
Undervoltage Lockout Hysteresis
Power-On Reset (POR) Threshold
POR Threshold Hysteresis
Standby Supply Current
Operating Current
Average Operating Current
SMBus static
During conversion
0.25 conversions/s
2 conversions/s
V
CC
, falling edge
1.5
V
CC
UVLO
Falling edge of V
CC
disables ADC
T
A
= +60°C to +100°C, V
CC
= +3.3V
T
A
= 0°C to +100°C, V
CC
= +3.3V
T
A
= -55°C to +125°C, V
CC
= +3.3V (Note 2)
3.0V
≤
V
CC
≤
5.5V
3.0
2.60
2.80
90
2.0
90
3
0.5
40
150
10
1.0
70
250
2.5
SYMBOL
CONDITIONS
MIN
1
8
0.125
11
-1.0
-3.0
-5.0
-2.0
-3.0
-5.0
-1.0
-3.0
-5.0
-2.0
-3.0
-5.0
0.2
+1.0
+3.0
+5.0
+2.0
+3.0
+5.0
1.0
3.0
+5.0
+2.0
+3.0
+5.0
0.6
5.5
2.95
m°C/V
V
V
mV
V
mV
µA
mA
µA
°C
°C
°C
°C
TYP
MAX
UNITS
°C
Bits
°C
Bits
Remote Temperature Error
(MAX6657)
2
_______________________________________________________________________________________