欢迎访问ic37.com |
会员登录 免费注册
发布采购

MAX6654MEE 参数 Datasheet PDF下载

MAX6654MEE图片预览
型号: MAX6654MEE
PDF下载: 下载PDF文件 查看货源
内容描述: 1 ° C精度的远端/本地温度传感器,带有SMBus串行接口 [1∑C Accurate Remote/Local Temperature Sensor with SMBus Serial Interface]
分类和应用: 传感器换能器温度传感器输出元件
文件页数/大小: 16 页 / 222 K
品牌: MAXIM [ MAXIM INTEGRATED PRODUCTS ]
 浏览型号MAX6654MEE的Datasheet PDF文件第6页浏览型号MAX6654MEE的Datasheet PDF文件第7页浏览型号MAX6654MEE的Datasheet PDF文件第8页浏览型号MAX6654MEE的Datasheet PDF文件第9页浏览型号MAX6654MEE的Datasheet PDF文件第11页浏览型号MAX6654MEE的Datasheet PDF文件第12页浏览型号MAX6654MEE的Datasheet PDF文件第13页浏览型号MAX6654MEE的Datasheet PDF文件第14页  
1°C Accurate Remote/Local Temperature  
Sensor with SMBus Serial Interface  
Write Byte Format  
S
ADDRESS  
WR  
ACK  
COMMAND  
ACK  
DATA  
ACK  
P
7 bits  
8 bits  
8 bits  
1
Slave Address: equiva-  
lent to chip-select line of  
a 3-wire interface  
Command Byte: selects which  
register you are writing to  
Data Byte: data goes into the register  
set by the command byte (to set  
thresholds, configuration masks, and  
sampling rate)  
Read Byte Format  
S
ADDRESS  
WR  
ACK  
COMMAND  
ACK  
S
ADDRESS  
RD  
ACK  
DATA  
///  
P
7 bits  
8 bits  
7 bits  
8 bits  
Slave Address: equiva-  
lent to chip-select line  
Command Byte: selects  
which register you are  
reading from  
Slave Address: repeated  
due to change in data-  
flow direction  
Data Byte: reads from  
the register set by the  
command byte  
Send Byte Format  
Receive Byte Format  
S
ADDRESS WR ACK COMMAND ACK  
P
S
ADDRESS  
RD  
ACK DATA  
8 bits  
///  
P
7 bits  
8 bits  
7 bits  
Data Byte: reads data from  
the register commanded  
by the last Read Byte or  
Write Byte transmission;  
also used for SMBus Alert  
Response return address  
Command Byte: sends com-  
mand with no data, usually  
used for one-shot command  
S = Start condition  
P = Stop condition  
Shaded = Slave transmission  
/// = Not acknowledged  
Figure 3. SMBus Protocols  
A
B
C
D
E
F
G
H
I
J
K
L
M
t
t
HIGH  
LOW  
SMBCLK  
SMBDATA  
t
t
t
t
HD:DAT  
HD:STA  
SU:STA  
SU:DAT  
t
t
SU:STO  
BUF  
A = START CONDITION  
F = ACKNOWLEDGE BIT CLOCKED INTO MASTER  
G = MSB OF DATA CLOCKED INTO SLAVE  
H = LSB OF DATA CLOCKED INTO SLAVE  
I = SLAVE PULLS SMBDATA LINE LOW  
J = ACKNOWLEDGE CLOCKED INTO MASTER  
K = ACKNOWLEDGE CLOCK PULSE  
L = STOP CONDITION, DATA EXECUTED BY SLAVE  
M = NEW START CONDITION  
B = MSB OF ADDRESS CLOCKED INTO SLAVE  
C = LSB OF ADDRESS CLOCKED INTO SLAVE  
D = R/W BIT CLOCKED INTO SLAVE  
E = SLAVE PULLS SMBDATA LINE LOW  
Figure 4. SMBus Write Timing Diagram  
A
B
C
D
E
F
G
H
I
J
K
L
M
t
t
HIGH  
LOW  
SMBCLK  
SMBDATA  
t
t
t
t
t
BUF  
SU:STA HD:STA  
SU:DAT  
SU:STO  
A = START CONDITION  
E = SLAVE PULLS SMBDATA LINE LOW  
I = MASTER PULLS DATA LINE LOW  
J = ACKNOWLEDGE CLOCKED INTO SLAVE  
K = ACKNOWLEDGE CLEAR PULSE  
J = STOP CONDITION, DATA  
EXECUTED BY SLAVE  
K = NEW START CONDITION  
B = MSB OF ADDRESS CLOCKED INTO SLAVE  
C = LSB OF ADDRESS CLOCKED INTO SLAVE  
D = R/W BIT CLOCKED INTO SLAVE  
F = ACKNOWLEDGE BIT CLOCKED INTO MASTER  
G = MSB OF DATA CLOCKED INTO MASTER  
H = LSB OF DATA CLOCKED INTO MASTER  
Figure 5. SMBus Read Timing Diagram  
10 ______________________________________________________________________________________