1°C Accurate Remote/Local Temperature  
Sensor with SMBus Serial Interface  
until cleared. (The conditions for clearing an ALERT  
Table 4. Read Format for Alert Response  
Address (0001100)  
vary depending on the type of slave device. Successful  
reading of the alert response address clears the inter-  
rupt latch provided that the condition that caused the  
ALERT has already ceased. The ALERT is cleared after  
the slave address has been returned to the host.)  
BIT  
NAME  
FUNCTION  
7
ADD7  
(MSB)  
Command Byte Functions  
The 8-bit command byte register (Table 5) is the master  
index that points to the various other registers within the  
MAX6654. The registers POR state is 0000 0000, so  
that a Receive Byte transmission (a protocol that lacks  
the command byte) that occurs immediately after POR  
returns the current local temperature data. The one-  
shot command immediately forces a new conversion  
cycle to begin. If the one-shot command is received  
when the MAX6654 is in software standby mode  
(RUN/STOP bit = high), a new conversion is begun,  
after which the device returns to standby mode. If a  
conversion is in progress when a one-shot command is  
received, the command is ignored. If a one-shot com-  
mand is received in autoconvert mode (RUN/STOP bit  
= low) between conversions, a new conversion begins,  
the conversion rate timer is reset, and the next automat-  
ic conversion takes place after a full delay elapses.  
6
5
4
3
2
1
ADD6  
ADD5  
ADD4  
ADD3  
ADD2  
ADD1  
Provide the current MAX6654  
slave address that was latched at  
POR (Table 9)  
0
1
Logic 1  
(LSB)  
Alert Interrupts  
The ALERT interrupt output signal is latched and can  
only be cleared by either reading the status register or  
by responding to an Alert Response address, if the  
fault condition has ceased. Interrupts are generated in  
response to T  
and T  
comparisons and when  
LOW  
HIGH  
the remote diode is disconnected (for continuity fault  
detection). The interrupt does not halt automatic con-  
versions; new temperature data continues to be avail-  
able over the SMBus interface after ALERT is asserted.  
The interrupt output pin is open drain so that multiple  
devices can share a common interrupt line. The inter-  
rupt rate can never exceed the conversion rate.  
Configuration Byte Functions  
The configuration byte register (Table 6) is a read-write  
register with several functions. Bit 7 is used to mask  
(disable) interrupts. Bit 6 puts the MAX6654 into soft-  
ware standby mode (STOP) or autoconvert (RUN) mode.  
Bit 5 selects the extended temperature range mode,  
which allows temperature data to be read down to  
-651C. Bit 4 puts the MAX6654 into parasitic resistance  
cancellation mode (PRCM), which can reduce tempera-  
ture measurement errors due to resistance in series with  
the sensing junction. Bit 3 should always be set to one  
(not the default value for operation with the CPU). Bits 2,  
1, and 0 are internally set to one.  
The MAX6654 responds to the SMBus Alert Response  
address, an interrupt pointer return-address feature  
(see Alert Response Address section). Prior to taking  
corrective action, always check to ensure that an inter-  
rupt is valid by reading the current temperature.  
Alert Response Address  
The SMBus Alert Response interrupt pointer provides  
quick fault identification for simple slave devices that  
lack the complex, expensive logic needed to be a bus  
master. Upon receiving an ALERT interrupt signal, the  
host master can broadcast a Receive Byte transmission  
to the Alert Response slave address (0001 100). Then  
any slave device that generated an interrupt attempts  
to identify itself by putting its own address on the bus  
(Table 4).  
Parasitic Resistance Cancellation Mode  
Resistance in series with the remote-sensing junction  
causes conversion errors on the order of 0.51C per  
ohm. The MAX6654 can cancel the effect of parasitic  
series resistance by using the PRCM. If bit 4 of the con-  
figuration byte is set HIGH, then the PRCM is invoked,  
provided the conversion rate is set 1Hz. If the conver-  
sion rate is faster than this, then the setting of bit 4 in  
the configuration register is ignored. In the PRCM, the  
conversion time is doubled (to typically 500ms to read  
both local and remote diodes) but external resistances  
as high as 100can be compensated.  
The Alert Response can activate several different slave  
devices simultaneously, similar to the I2C General Call.  
If more than one slave attempts to respond, bus arbitra-  
tion rules apply, and the device with the lower address  
code wins. The losing device does not generate an  
acknowledge and continues to hold the ALERT line low  
12 ______________________________________________________________________________________