Overvoltage Protection Controllers  
with Reverse Polarity Protection  
5L/MAX4867  
R
C
R
D
1MΩ  
1.5kΩ  
I
100%  
90%  
PEAK-TO-PEAK RINGING  
(NOT DRAWN TO SCALE)  
I
P
r
DISCHARGE  
RESISTANCE  
CHARGE-CURRENT  
LIMIT RESISTOR  
AMPERES  
HIGH-  
VOLTAGE  
DC  
DEVICE  
UNDER  
TEST  
36.8%  
C
s
100pF  
STORAGE  
CAPACITOR  
10%  
0
SOURCE  
TIME  
0
t
RI  
t
DL  
CURRENT WAVEFORM  
Figure 7. Human Body ESꢀ Test Model  
Figure 8. Human Body Current Waveform  
R
C
R
D
I
50MΩ TO 100MΩ  
330Ω  
100%  
90%  
DISCHARGE  
RESISTANCE  
CHARGE-CURRENT  
LIMIT RESISTOR  
HIGH-  
VOLTAGE  
DC  
DEVICE  
UNDER  
TEST  
C
150pF  
STORAGE  
CAPACITOR  
s
SOURCE  
10%  
t = 0.7ns TO 1ns  
R
t
30ns  
60ns  
Figure 9. IEC ±000-4-2 ESꢀ Test Model  
Figure ±0. IEC ±000-4-2 ESꢀ Generator Current Waveform  
erally lower than that measured using the Human Body  
Model. Figure ±0 shows the current waveform for the  
±8kV IEC ±000-4-2 Level 4 ESꢀ Contact ꢀischarge test.  
The Air-Gap test involves approaching the device with a  
charger probe. The Contact ꢀischarge method connects  
the probe to the device before the probe is energized.  
IEC 1000-4-2  
Since January ±996, all equipment manufactured  
and/or sold in the European Union has been required to  
meet the stringent IEC ±000-4-2 specification. The IEC  
±000-4-2 standard covers ESꢀ testing and perfor-  
mance of finished equipment. It does not specifically  
refer to ICs. The MAX4864L/MAX4865L/MAX4866L/  
MAX4867 help users design equipment that meets  
Level 3 of IEC ±000-4-2, without additional ESꢀ-protec-  
tion components.  
Chip Information  
PROCESS: BiCMOS  
The main difference between tests done using the  
Human Body Model and IEC ±000-4-2 is higher peak  
current in IEC ±000-4-2. Because series resistance is  
lower in the IEC ±000-4-2 ESꢀ test model (Figure 9), the  
ESꢀ-withstand voltage measured to this standard is gen-  
_______________________________________________________________________________________  
9